hager S145-22X Manual De Instalación página 75

Detector movimiento ip55,radio, fachada inmune mascotas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
The lower beam is adjusted according to the position of the lens as the figures show it below.
To adjust the range of detection:
1. Separate the support from
lens and the cover as
indicated.
2. Adjust the detection ranges separately by sliding the lenses
vertically to marks A, B, C or D.
Height of installation 1 m
* The maximum range can vary from the standard
Position A (12 m)
CAuTIon: the lenses
must not be positioned
crossways in the
lens support.
Position B (8 m)
Position C (5 m)
Position D (2 m)
Position
Standard range
Maximum range*
(m)
(m)
A
12
10 - 15
B
8
6 - 10
C
5
4 - 6
D
2
1.5 - 3
values according to the environmental conditions.
(m)
1
5
(m)
1
5
(m)
1
5
(m)
1
5
75
3. If you wish to adjust the
detection angle horizontally,
go to the next paragraph.
Otherwise, put the lens
support back in place.
Check that it is held firmly
on either side by the six
cover slots.
Top
depolarising
slot
10
12(m)
12(m)
10
12(m)
10
12(m)
10
GB
Slots
Bottom
closing
screw