Operating Test; Detection Zone Test; Real Test; Maintenance - hager S145-22X Manual De Instalación

Detector movimiento ip55,radio, fachada inmune mascotas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
GB

8.1 Detection zone test

1. Put DIP switch 1 in the ON
position.
2. Close the detector cover.
3. Switch the control panel to
test mode:
engineer
installer code
4. Check the area of detection
using the indicator LED and
adjust the detector if need be.
With each detection the
control panel issues the voice
message "Beep, intrusion or
Beep prealarm, detector X".
5. Switch the control panel back
to installation mode, press:
engineer
installer code
6. Reopen the cover, to put DIP
switch 1 to OFF.
Close the detector cover and
tighten the locking screw.

8.2 Real test

1. Switch the control panel to
user mode:
engineer
installer code
2. Put your control panel in Total
Arm mode.
3. Wait for the exit time delay.
4. Cross over the protected area
and check that the control
panel responds (see your
control panel's installation
manual).

9.1 Fault indication

The control panel takes battery
faults, anti-tamper faults and
radio faults on the detector into
account.
Battery fault
Following a system command,
the control panel issues the
following voice message: "beep,
fault, battery, detector X".
Anti-tamper fault
Following a system command,
the control panel issues the
following voice message: "beep,
fault, anti-tamper, detector X".
Radio fault
Following a system command,
the control panel issues the
following voice message: "beep,
fault, radio, detector X".
CAuTIon: the test button makes it possible to check if the battery
is oK. The indicator on the radio board lights red when the button
is pressed.
78

9.2 Changing the battery

CAuTIon: the detector's
configuration is saved when the
battery is changed.
1. Switch the control panel to
installation mode and ask the
master user to press:
master
code
then press:
engineer
installer code
2. Open the case of the detector
(see § Opening the detector).
3. Replace the used lithium
batery.

Publicidad

Tabla de contenido
loading

Tabla de contenido