It is not possible to use this pipe for any other purpose. This smokestack must be shared with
other devices
(You can see G: Technical characteristics).
1.8. Insulating procedures.
1.8.1. Apparatus insulation. The fireplace must be insulated with insulation panels (Type A-
1,EN13501-1) on its sides, back and upper part.
1.8.2 Fireplace room insulation. It is also convenient to use insulation panels on the inner walls
of the fireplace (Type A-1, EN13501-1).
1.9. Safety distances.
1.9.1. Inner fireplace room safety distances. You must be respected the values described in G:
Technical characteristics.
1.9.2. Outer fireplace safety distances. Anything fragile or flammable (textile, electronics, wood,
paper wall, glass, chalk...) should be separated of the appliance and respected the safety
distances described in G: Technical characteristics.
We must take special care in those fireplaces with wooden shelves or similar: we must prevent
and avoid the possibility of hot air that expels the device falls directly on the wood, in these cases,
flammable items should be properly insulated.
1.10. Ventilation
1.10.1. Ventilation of the fireplace enclosure (C14-C15-C16). In order to have a good air
circulation, some air vents must be placed at the inlet and outlet of the fireplace niche, following
the minimum sections described in the table of Technical features.
The air in the chamber of the device can be conducted to the top of the fireplace or to an adjacent
room. To do this, you have to remove the lids, screw up the collars and connect the pipe (it can be
rigid and galvanized or flexible and made of aluminium) (C17).
1.10.2. External air intake. The necessary air intake for the combustion is possible thanks to a
connector at the bottom rear of the module. (C18). This air intake may be from outside the home,
or a ventilated garage or basement. If this intake is not performed, then this adapter must not be
removed: a conduit from the connector to the lower vent diffuser will be placed instead. Placing an
external grating should not make decrease the air inlet section above indicated. A proper air intake
for combustion inside the fireplace enclosure must be performed, so that it is not completely
sealed.
1.10.4. Ventilation of the device (C19). The device comes from the factory with some openings
at the rear and the sides of the chamber:
Ventilation with turbine kit (optional). If the device is installed with the turbine kit (optional) it is
-
not necessary to make additional openings, they are already done.
Natural convection ventilation (without turbine). If the device is installed without the turbine kit
-
(optional), then all the lids must be opened (rectangular lids).
CAUTION:
Once all the lids are opened, IT IS NOT POSSIBLE TO INSTALL
THE VENTILATION KIT (TURBINE) -OPTIONAL- IN THE MODULE
anymore.
1.11. Niche of the fireplace.
and always avoiding contact points. There must not contain any flammable or fragile materials
inside, such as wood, wallpaper, glass, chalk paper, etc. Possible appliance adjustments. It is
possible that the installation, the appliance is adjusted, if so, the following steps:
1.12. Inside the fireplace.
1.12.1. Placing the vermiculite pieces inside the fireplace. The vermiculite pieces are already
placed from the factory. To avoid weight at the time of installing these pieces, they can be
removed and, once the fireplace is installed, they must be replaced (C21-C22-C23-C24).
1.13. Placing the deflector shields.
It must be built with non-combustible materials, never over the module
Pag. 14