2.4. Fire types. This apparatus is an on and off fire. The smoke chamber must be closed except
when being loaded, to avoid any smoke out fuel debris. It is convenient when loading the fireplace,
to avoid any leak or smoke escape.
2.5. Authorized fuel.
forbidden by the manufacturer's authorized. As fuel only use natural wood logs is not advisable
to use resinous wood is allowed.
Are forbidden other fuels, including liquid (sometimes used to start the fire).
The maximum length of the logs should not exceed the length specified in the technical data
according to model (
2.6. Loading and reload fuel. It must take into account the maximum authorised load of fuel,
ensuring that when the recharge. The fuel can't overtake the limit, taking care not to exceed either
in quantity or size to the data specified above
WARNING - IMPORTANT NOTE:
Interior parts vermiculite SHOULD NOT BE HIT, especially when
done refueling.
If any of these parts are cracked, but is properly placed in your
site, does not alter the proper functioning of NI A POTENTIAL RISK. The device
can be used normally.
These cracks do not pose any manufacturing defects so you do not fall under
warranty.
To light the fire using materials suitable for this purpose, such as fire pads, gel fire, paper and dry
and thin branches. DO NOT USE GASOLINE, SOLVENTS OR ALCOHOL.
To make the procedure ignition follow these steps: placing the burden on the central area of the
database from home, open the register primary and secondary maximum and then fire pledge.
Once the fire is lit, close the primary register to prevent excessive combustion and control the
intensity by the secondary registers.
When the fuel load is reduced you will have to recharge considering data specified above.
2.7. Loading door.
2.7.1. Operation of the guillotine-type opening system. The door is opened from up to down.
This function is very useful for loading the combustible.
2.7.2. Operation of the swing door opening (C30). This function is useful for cleaning or
changing the glass, joints, etc. To open the door, use the specific tool. You have to fit it into the
upper door frame while pulling it to the left and swilling the door down.
2.8. Mechanisms lock. It is absolutely necessary to revise the proper functioning of the guillotine-
type and swing opening systems, as well as the primary and secondary registers, etc. after a long
downtime. It is also recommended to check the external air intakes that supply air for combustion;
they must be free of any blockage.
2.9. Cleaning and maintenance.
2.9.1. Glass cleaning. To clean the glass, the appliance must not be operating. Do not clean with
any liquid either the metal parts of the door or the seal, in order to prevent damage.
2
.9.2. Emptying of the ashtray drawer. Empty the tray only when the device is completely off,
ensuring the ashes do not contain burning embers which may cause a fire; in any case they
must be placed in a metal bucket.
The removal of this tray can be done from the top (C31) or the bottom (C32).
For the latter option, it is possible to acquire a small door with a grating – See section E-F:
Optional components: Feasible inlet diffuser – (ask your distributor Rocal).
The appliance should not be used as an incinerator and other fuels that are
see Table G: Technical characteristics).
(you can see the G: Technical Characteristics).