A-28 / ENGLISH

TROUBLESHOOTING

If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Nilfi sk-Advance
Service Center immediately for service.

TRIPPING THE CIRCUIT BREAKERS

The circuit breakers are located on the Circuit Breaker Panel in the operator's compartment; they protect electrical circuits and motors from
damage due to overload conditions. If a circuit breaker trips, try to determine the cause.
Accessory Circuit 1 Circuit Breaker (25 Amp) Possible cause may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Accessory Circuit 2 Circuit Breaker (15 Amp) Possible cause may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Ignition Circuit Circuit Breaker (10 Amp) Possible cause may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Starter Motor Circuit Breaker (15 Amp) Possible cause may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Main Circuit Breaker (60 Amp) Possible cause may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Horn Circuit Breaker (10 Amp) Possible cause may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Headlight / Tail Light Circuit Breaker (15 Amp) Possible cause may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Shaker Motor Circuit Breaker (15 Amp) Possible causes may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
2
Overloaded or jammed shaker motor (check shaker motor)
AXP/EDS Circuit Breaker (10 Amp) Possible causes may be:
1
Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Once the problem has been corrected, push the button in to reset the circuit breaker. If the button does not stay in, wait 5 minutes and try
again. If the circuit breaker trips repeatedly, call your Nilfi sk-Advance Service Center for service.
A-28 - FORM NO. 56041580 - Captor
4300, 4800, 5400 / CR 1100, 1200, 1400
revised 11/07