2.2 HOURMETER=
NORESET
The Hourmeter tracks hours of operation
maintenance:
for scheduled
Therewill be a one time break in "CHGOIL" messagethat flashes
with the elapsedtime in hours and tenths after the first 30 hours
of operation.
This messagewill actually begin flashing at 29 hours and disable
itself at 31 hours providing a two hour window to perform the
service.
Therewill be a subsequent"CHGOIL" messageevery 100 hours.
The message wilt flash one hour before and one hour after each
100 hour interval, again providing a two hour window to perform
service.
Every 200 hours the "SVC" icon on the lower left hand corner of
the display will flash. The messagewill flash one hour before and
one hour after each 200 hour interval providinga two hour window
to perform service.
Whenthe hour meter is in the FlashAlert mode, the maintenance
message will always alternate with elapsed time in hours and
tenths. The hours wilt flash four times, then alternate with the
maintenancemessagefour times until the meter resets itself.
,, 100 hours - CHGOIL-- Oil ChangeInterval(Every 100 hrs)
* 200 hours - SVC-- Air Filter Interval (Every200 hrs)
2.3 HOURMETEB=WITH
RESET
TheHourmetertracks hoursof operationfor scheduledmaintenance
(see chart).
Operation: Push and releasethe reset button to toggle between
screens. The hours count backwards from the set interval as
shown in the chart.
Whenthe meter reaches5 hours,thetext "CHGOIL" (or "SVCAIR
FILTER"or "CHG PLUG")will flash continually for two minutes.
After this time, the meter will go back to displaying the total hours
of the unit (for 2 minutes). This cyle will repeatfor the entire 5
hours.
When the service interval reaches zero hours, the text "NOW"
replacesthe hours remaining.
For a new generatorfor instance, the messagewill say "CHGOIL"
thenflash "in 30". This meansthat in 30 hours, the oil wilt needto
be changed. Pressingthe button a few more times will bring the
meter back to the screenthat shows the total hours run.
Reset: Toggleto the alert that you wish to reset then hold the
button down for 9 seconds.The maintenancehours are resetwhen
the display shows "0000.0".
NOTE:
The hour glass graphic will flash on and off when the engine
is running. T his signifiesthat the meter is trackinghours of
operation.
Figure 4 - Hourmeter
OOOO'O
HOUR GLASS
RESET BUTTON
GRAPHIC
(IF EQUIPPED)
2.4 CORD SETS ANDCONNECTION
PLUGS
2.4.1 120 VAC,20 AMP,GFC/DUPLEX RECEPTACLE
This is a 120 Volt outlet protectedagainst overloadby a 20 Amp
push-to-reset circuit breaker (Figure5). Use each socket to power
120 Volt AC, single phase, 60 Hz electrical loads requiringup to a
combined 2400 watts (2.4 kW) or 20 Amps of current. Use only
high quality, welt-insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). A cord set 15 feet or shorter
is preferred.
Keepextensioncords as short as possibleto preventvoltage drop
and possible overheatingof wires.
Nourmeter(With Reset) Chart
Message
Frequency of Message
Interval
Duration of message
CHG OIL
Initial break-in period
First 30 Hours
CHG OIL
Re-occuring
100 hours
ON/OFF for 2 minutes in a 5
SVCAIR FILTER
Re-occuring
200 hours
hour period
CHGPLUG
Re-occuring
200 hours