Fitting the ∅ 110 mm inlet
The ProfiClear Compact/Classic pump chamber can be fitted as the end unit both for the ProfiClear
Premium Compact filter series and the ProfiClear Classic filter series. Depending on which unit is used,
the inlet has to be fitted higher or lower and the opening in the container wall that is not used must remain
or be closed.
ProfiClear Classic: Use the top opening.
ProfiClear Premium Compact: Use the bottom opening.
How to proceed:
E
1. If not already done: Fit the seal into the wall of the container from the outside. Ensure that the hole
pattern of the seal is aligned to the hole pattern of the container.
2. Fit the inlet to the seal.
Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
−
3. Fasten the seal and inlet from the inside with oval head screws.
−
Tighten all screws diagonally using the cordless screwdriver to ensure that the sealing ring is
uniformly applied. Further tighten the screws using a Phillips screwdriver.
4. Fit the rubber sleeve over the inlet and fasten with a hose clip.
−
Turn the hose clip so that the screw is accessible from the side. This facilitates later installation
work.
Fitting the DN 110 outlet
How to proceed:
F
1. Fit the O ring onto the outlet.
2. Fit the outlet into the respective hole of the container wall from the outside.
Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
−
3. Fasten the outlet from the inside with oval head screws.
−
Tighten all screws diagonally using the cordless screwdriver to ensure that the sealing ring is
uniformly applied. Further tighten the screws using a Phillips screwdriver.
4. If necessary: Close the outlet with the cover cap or connect further DN 110 pipes.
Fitting the 2" outlet
How to proceed:
G
1. Push the flat seal onto the 2" connection.
2. Insert the 2" connection (long side first) from the inside into the hole.
3. Secure the 2" connection with the star grip nut.
4. Screw the 2" hose connector with flat seal and union nut from the inside onto the 2" connection.
5. Either screw the cover cap with flat seal or the 2" hose connector with flat seal and union nut from the
outside onto the 2" connection.
Fitting the DN 75 slide valve
How to proceed:
H
1. Fit the slide valve into the connecting sleeve and secure with a hose clip.
2. Fit the connecting sleeve onto the connection.
3. Secure the holding plate of the slide valve to the outside of the container with cap nuts.
4. Secure the hose clip on the connection.