- EN -
2.4
Intended use
ProfiClear Pumpenkammer Compact/Classic, referred to in the following as "unit", may only be used as
specified in the following:
The following restrictions apply to the unit:
►
Only operate with water at a water temperature of +4 °C to +35 °C.
►
Never use the unit to convey fluids other than water.
►
Never run the unit without water.
►
Do not use for commercial or industrial purposes.
Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
►
3.
Safety information
This unit can be used by children aged 8 and above and by persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they are
supervised or have been instructed on how to use the unit in a safe way and they
understand the hazards involved.
Do not allow children to play with the unit.
Only allow children to carry out cleaning and user maintenance under supervision.
3.1
Hazards encountered by the combination of water and electricity
►
The combination of water and electricity can lead to death or severe injury from electrocution, if the
unit is incorrectly connected or misused.
►
Prior to reaching into the water, always switch off the mains voltage to all units used in the water.
4.
Installation
►
The following tools are required:
10 mm ring spanner
−
−
7 mm socket spanner, 8 mm socket spanner
−
PZ3 Phillips screwdriver
−
Cordless drill/screwdriver with PZ3 bit (do not set to "drill"!)
4.1
Preparing the unit connection
Before installing, connecting and starting up the unit, perform the following tasks:
Fit either 1 × ∅ 110 mm inlet ( A 8)
−
or (option for connection to ProfiClear Premium filter series) close ∅ 110 mm inlet and fit 1 × 150
−
mm connection ( A 9)
Fit 2 × DN 110 outlets ( A 2)
−
Fit 1 × 2" outlet ( A 3)
−
Fit 1 × DN 75 slide valve ( A 7)
−
►
Remove the container cover to perform the following work.
20