- EN -
4.2
Installing the filter pump in the container
A maximum of two AquaMax Gravity Eco or AquaMax Eco Premium filter pumps can be installed in the
pump chamber. The DN 110 outlet or the 2" outlet are used as outlets. Any connections that are not used
must be closed off with the supplied plugs.
4.2.1
Connecting the AquaMax Gravity Eco pump to the DN 110 outlet
A maximum of two Bitron Gravity UVC clarifiers can be installed in the pump chamber in conjunction
►
with two AquaMax Gravity Eco pumps. Please refer to the Bitron Gravity operating manual for
information about installation.
To ensure optimum connection of an AquaMax Gravity Eco pump to a DN 110 outlet, use a pipe
connection consisting of the combination (DN 110): 45° connection bend - short straight pipe - 45°
connection bend - short straight pipe.
How to proceed:
I
1. Prepare the filter pump according to the attendant operating manual with the connection adapter for
the DN 110 connection.
2. Align the pipe connection (consisting of two 45° connection bends and coupling sleeve) for connecting
the filter pump to the DN°110 connection and glue together. Then fasten it to the connection adapter
of the filter pump (secure using a pipe clip or glue). Place the filter pump in the container.
3. Connect the pipe connection to the DN 110 connection in the same way.
4.2.2
Connecting the AquaMax Gravity Eco pump to the 2" outlet
How to proceed:
J
1. Fit a 2" hose connector with flat seal inserted and union nut to the filter pump.
2. Fit a 2" hose connector with flat seal inserted and union nut from the inside to the 2" connection.
3. Connect the hose and secure both ends with hose clips.
4.2.3
Connecting the AquaMax Eco Premium pump to the 2" outlet
The pump chamber offers space for installing one AquaMax Eco Premium filter pump. The filter pump is
connected to the 2" outlet. A 2" hose used for the connection should be connected to the filter pumps via
a connection bend.
OASE recommends the 2" connection bend, Order No.: 50540.
How to proceed:
K
1. Fit the O ring onto the outlet.
2. Fit the outlet into the respective hole of the container wall from the outside.
−
Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
3. Fasten the outlet from the inside with oval head screws.
4.3
Installing a UVC clarifier in the container
►
A maximum of two Bitron Gravity UVC clarifiers can be installed in the pump chamber in conjunction
with two AquaMax Gravity Eco pumps. Please refer to the Bitron Gravity operating manual for
information about installation.
22