C. Objetos de Ethernet/IP del CPX-FB36
C.2

Objetos para ajustes de red

C.2.1 Objeto Device Level Ring
C-8
Clase de objeto: 71
Instancias:
1
Atr.
Acceso
Descripción
N.°
1
Get
Network Topology:
0: Linear
1: Ring
2
Get
Network Status:
0: Normal
1: Ring Fault
2: Unexpected loop detected
3: Partial network fault
4: Rapid fault / restore cycle
10
Get
Active Supervisor Address:
– Supervisor IP address
– Supervisor MAC address
12
Get
Capability Flags
Bit 0:
Bit 1:
Bit 2 ... 4: reserved. Shall be set to
Bit 5:
Bit 6 ... 31:reserved. Shall be set to
Bits 0 and 1 are mutually exclusive
1)
Especificación de EtherNet/IP, capítulo 9-5.4
Tab. C/6: Ajustes de red con objeto Device Level Ring