Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

NT 50/1 Me Classic
NT 50/2 Me Classic
NT 70/2 Me Classic
NT 90/2 Me Classic
Español
5
Português do
13
Brasil
English
21
Français
29
59652950
10/15

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Kärcher NT 50/1 Me Classic

  • Página 1 NT 50/1 Me Classic Español NT 50/2 Me Classic Português do Brasil NT 70/2 Me Classic English NT 90/2 Me Classic Français 59652950 10/15...
  • Página 2 NT 50/1...
  • Página 3 “Click”...
  • Página 5: Tabla De Contenido

    Antes del primer uso de su apa- Los aparatos viejos contienen rato, lea este manual original, materiales valiosos reciclables actúe de acuerdo a sus indicaciones y que deberían ser entregados guárdelo para un uso posterior o para otro para su aprovechamiento poste- propietario posterior.
  • Página 6: Elementos Del Aparato

    Elementos del aparato Montar el fieltro filtrante Solo NT 50/1, NT 50/2: 1 Tornillo en estrella Figura 2 Filtro de cartuchos  Desbloquear y extraer el cabezal de as- 3 Protección mecánica antiderrame (flo- piración. tador)  Insertar la bolsa de fieltro filtrante (ac- 4 Cabezal de aspiración cesorio especial) y respetar la posición 5 Manguera de aspiración...
  • Página 7: Manejo

    Figura Después de cada puesta en marcha  Montar el filtro de partículas gruesas de  Vacíe el recipiente. suciedad (accesorio especial).  Limpie el aparato por dentro y por fuera  Atornille el tornillo de estrella. aspirándolo y frotar con un paño húme- ...
  • Página 8: Ayuda En Caso De Avería

     Solo NT 70/2, NT 90/2: Limpiar la protección mecánica Comprobar si la tubería de salida es es- antiderrame tanca.  Desbloquear y extraer el cabezal de as- Pérdida de polvo durante la piración. aspiración  Desatornillar el tornillo de estreclla y ex- traer el filtro de cartucho.
  • Página 9: Datos Técnicos

    Datos técnicos NT 50/1 Me NT 50/1 Me NT 50/1 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tensión de red Frecuencia AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Corriente nominal Potencia Máx. 1150 1450 Potencial nominal 1050...
  • Página 10 NT 50/2 Me NT 50/2 Me NT 50/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tensión de red Frecuencia AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Corriente nominal Potencia Máx. 2200 Potencial nominal 1950 2500 Capacidad del depósito...
  • Página 11 NT 70/2 Me NT 70/2 Me NT 70/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tensión de red Frecuencia AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Corriente nominal Potencia Máx. 2200 Potencial nominal 1950 2500 Capacidad del depósito...
  • Página 12 NT 90/2 Me NT 90/2 Me NT 90/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tensión de red Frecuencia AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Corriente nominal Potencia Máx. 2200 Potencial nominal 1950 2500 Capacidad del depósito...
  • Página 13: Proteção Do Meio-Ambiente

    Leia o manual de instruções ori- Os aparelhos velhos contêm ginal antes de utilizar o seu apa- materiais preciosos e deverão relho. Proceda conforme as indicações no ser reutilizados. Baterias, óleo e manual e guarde o manual para uma con- produtos similares não podem sulta posterior ou para terceiros a quem ser descartados no meio am-...
  • Página 14: Elementos Do Aparelho

    Montar o saco de filtro de velo Elementos do aparelho Somente NT 50/1, NT 50/2: 1 Parafuso em cruz Figura 2 Filtro de cartucho  Destravar e retirar o cabeçote de aspi- 3 Proteção mecânica de transbordo (flu- ração. tuador) ...
  • Página 15: Manuseamento

     Montar e travar o cabeçote de aspira- Guardar a máquina ção. Figura – Assim que se alternar da aspiração a  Guardar os bicos de chão, tubos de as- úmido para a aspiração a seco é neces- piração, mangueira de aspiração, tubo sário substituir o filtro de sujeira grossa curvado, bico de juntas e cabo de rede, por um filtro de cartucho e event.
  • Página 16: Limpar A Proteção Mecânica De Transbordo

     Somente NT 70/2, NT 90/2: Limpar a proteção mecânica de Controlar a estanqueidade da manguei- transbordo ra de descarga.  Destravar e retirar o cabeçote de aspi- Durante a aspiração sai pó ração.  Desaparafusar o parafuso em cruz e os ...
  • Página 17: Dados Técnicos

    Dados técnicos NT 50/1 Me NT 50/1 Me NT 50/1 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tensão da rede Frequência AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Corrente nominal Potência máx. 1150 1450 Potência nominal 1050...
  • Página 18 NT 50/2 Me NT 50/2 Me NT 50/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tensão da rede Frequência AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Corrente nominal Potência máx. 2200 Potência nominal 1950 2500 Conteúdo do recipiente...
  • Página 19 NT 70/2 Me NT 70/2 Me NT 70/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tensão da rede Frequência AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Corrente nominal Potência máx. 2200 Potência nominal 1950 2500 Conteúdo do recipiente...
  • Página 20 NT 90/2 Me NT 90/2 Me NT 90/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tensão da rede Frequência AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Corrente nominal Potência máx. 2200 Potência nominal 1950 2500 Conteúdo do recipiente...
  • Página 21: Environmental Protection

    Please read and comply with Danger or hazard levels these original instructions prior DANGER to the initial operation of your appliance and Immediate danger that can cause severe store them for later use or subsequent own- injury or even death. ers.
  • Página 22: Device Elements

    Install fleece filter bag Device elements NT 50/1, NT 50/2 only: 1 Star screw Illustration 2 Cartridge filter  Release and remove the suction head. 3 Mechanical overflow protection (float)  Fit fleece filter bag (optional accessory) 4 Suction head and ensure correct seating.
  • Página 23: Operation

    Drain off dirt water Transport NT 70/2, NT 90/2 only: CAUTION CAUTION Risk of injury and damage! Observe the Please observe the local provisions regard- weight of the appliance when you transport ing the wastewater treatment. Illustration  In order to transport the appliance over ...
  • Página 24: Troubleshooting

    Troubleshooting Customer Service If malfunction can not be fixed, the de- DANGER vice must be checked by customer ser- First pull out the plug from the mains before vice. carrying out any tasks on the machine. Warranty Suction turbine does not run ...
  • Página 25: Technical Specifications

    Technical specifications NT 50/1 Me NT 50/1 Me NT 50/1 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Mains voltage Frequency AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Rated current Max. performance 1150 1450 Rated power 1050 1300...
  • Página 26 NT 50/2 Me NT 50/2 Me NT 50/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Mains voltage Frequency AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Rated current Max. performance 2200 Rated power 1950 2500 Container capacity Filling quantity (liquid)
  • Página 27 NT 70/2 Me NT 70/2 Me NT 70/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Mains voltage Frequency AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Rated current Max. performance 2200 Rated power 1950 2500 Container capacity Filling quantity (liquid)
  • Página 28 NT 90/2 Me NT 90/2 Me NT 90/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Mains voltage Frequency AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Rated current Max. performance 2200 Rated power 1950 2500 Container capacity Filling quantity (liquid)
  • Página 29: Protection De L'environnement

    Lire ce manuel d'utilisation origi- Les appareils usés contiennent nal avant la première utilisation des matériaux précieux recy- de votre appareil, le respecter et le conser- clables lesquels doivent être ap- ver pour une utilisation ultérieure ou pour le portés à un système de recy- futur propriétaire.
  • Página 30: Éléments De L'appareil

    Mise en place du sac filtrant en toile Éléments de l'appareil Uniquement NT 50/1, NT 50/2 : 1 Vie en étoile Illustration 2 Filtre-cartouche  Déverrouiller et retirer la tête d'aspira- 3 Trop-plein mécanique (flotteur) tion. 4 Tête d'aspiration  Enficher le sac filtrant en feutre (acces- 5 Flexible d’aspiration soire en option) et veiller à...
  • Página 31: Utilisation

     Positionner la tête d'aspiration et la ver- Ranger l’appareil rouiller. Illustration – Pour passer de l'aspirateur de l'eau à  Ranger les buses pour sol, les tubes l'aspiration de poussières, le filtre pour d'aspiration, le flexible d'aspiration, le déchets volumineux doit être remplacé coude, le suceur fentes et le câble d'ali- par une cartouche filtrante et éventuel- mentation en respectant la figure.
  • Página 32: Assistance En Cas De Panne

     Uniquement NT 70/2, NT 90/2 : Nettoyer la sécurité anti- Contrôler l'étanchéité du flexible de vi- débordement mécanique dange.  Déverrouiller et retirer la tête d'aspira- De la poussière s'échappe lors de tion. l'aspiration  Dévisser la vis en étoile et retirer le filtre à...
  • Página 33: Caractéristiques Techniques

    Caractéristiques techniques NT 50/1 Me NT 50/1 Me NT 50/1 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tension du secteur Fréquence AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Courant nominal Puissance maximale 1150 1450 Puissance nominale 1050...
  • Página 34 NT 50/2 Me NT 50/2 Me NT 50/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tension du secteur Fréquence AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Courant nominal Puissance maximale 2200 Puissance nominale 1950 2500 Capacité...
  • Página 35 NT 70/2 Me NT 70/2 Me NT 70/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tension du secteur Fréquence AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Courant nominal Puissance maximale 2200 Puissance nominale 1950 2500 Capacité...
  • Página 36 NT 90/2 Me NT 90/2 Me NT 90/2 Me Classic Classic Classic *BR (127 V) *VEX *BR (220 V) Tension du secteur Fréquence AR: 1~ 50-60 1~ 60 1~ 60 BR: 1~ 60 Courant nominal Puissance maximale 2200 Puissance nominale 1950 2500 Capacité...
  • Página 37 NT 50/1 - NT 50/2 - NT 70/2 - NT 90/2...
  • Página 40 http://www.kaercher.com/dealersearch...

Este manual también es adecuado para:

Nt 50/2 me classicNt 70/2 me classicNt 90/2 me classic

Tabla de contenido