Wilo Stratos PICO-Z Serie Instrucciones De Instalación Y Funcionamiento página 31

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
Rotating the motor
head
3
2
1
6
Installation and operating instructions Wilo-Stratos PICO-Z
Caution: Damage to the pump!
The wrong materials can cause corrosion damage.
• When connecting to galvanised piping, use only red
brass screwed connections.
• Install shut-off devices upstream and downstream of
the pump to facilitate pump replacement.
Caution: Damage to the pump!
Leaking water may damage the control module.
• Align the upper shut-off device such that leaking
water cannot drip onto the control module (6).
• Align the upper shut-off device laterally.
• Complete all welding and brazing tasks.
• Flush the pipe system.
Rotate the motor head (3+6) before installing and con-
necting the pump.
• Hold the motor head (3+6) and unscrew the 4 housing
screws (2).
Caution: Damage to the inner gasket!
Damage to the inner gasket leads to leaks.
• Carefully rotate the motor head (3+6) without
removing it from the pump housing (1).
• Carefully rotate the motor head (3+6).
• Observe the allowable installation position (Fig. 2)
and the direction arrow on the pump housing (1).
• Tighten the 4 housing screws (2).
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Stratos pico-z 25/1-6

Tabla de contenido