Operation

Fill solution tank
Warning
Risk of damage. Only use the recom-
mended detergents. With respect to dif-
ferent detergents the operator bears the
increased risk regarding the operational
safety, accident risk and reduced prod-
uct life of the appliance. Only use deter-
gents that are free from solvents,
hydrochloric acid and hydrofluoric acid.
Note
Do not use highly foaming detergents.
Observe the chemical measuring notes.
Recommended detergents:
Application
Everyday cleaner, alka-
li-based
Everyday cleaner, acid-
ic, for sanitary applica-
tions, swimming pools,
etc. Removes limestone
deposits.
Remove the solution tank from the
appliance.
Open the cover of the solution tank.
Pour in water/detergent mixture.
Maximum temperature of the liquid
50 °C.
Close the cover of the solution tank.
Insert the solution tank into the appli-
ance.
Establish mains contact
Swivel bottom cable hook upward
and remove cable.
Check mains cable and plug for
damage or breakage. Get them re-
8
English
Risk of damage to the floor covering. Do
not operate the appliance for extended
period on the spot.
Normal soiling
Detergent
RM 743
Severe soiling
RM 738
Risk of damage to the floor covering.
The cleaning method for severe soiling
must only be used on floors suitable for
this kind of cleaning.
placed only through customer ser-
vice agent or an electrician.
Insert the plug into the socket.
Cleaning
Warning!
Move the squeegee lift pedal to posi-
tion „suction off" (Fig. 3 - position "1/
ON", see inside front cover).
Press the park position release and
swivel the handle toward the rear.
Set main switch for brush/vacuum
operation to "1".
Activate the water pump switch.
Move the appliance over the surface
to be cleaned.
Warning
Move the vacuum bar lift pedal to po-
sition „do not suction off" (Fig. 3 - po-
sition "0/OFF" see inside front cover)
and perform the cleaning as you
would with normal soiling. The deter-
gent liquid remains on the surface to
be cleaned and has time to settle in.
Move the squeegee lift pedal to posi-
tion "suction off" and reclean the sur-
face.
Complete cleaning
Turn off the water pump switch.
Push the appliance a little further to
vacuum up the remaining water.