Festo DNCE LAS Serie Instrucciones De Utilizacion página 31

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
DNCE−...−LAS
Pin
1
2
3
4
5
6
1
2
3
4
5
6
1)
A temperature sensor of type KTY11−5 from Infineon is used in the DNCE. The manu−
facturer's characteristic curves and technical data can be found in the Internet.
2)
BiSS/ physical protocol RS485/422
Fig. 7
BiSS interface measuring system
The BiSS interface is a 2−wire interface for interference−immune sensor connection.
In contrast to the SSI interface, data transmission is bidirectional, i.e. data can
also be written to the sensor, for example for parameterisation.
Data transmission takes place over a pulse wire and a data wire operated by the
sensor for serial transmission. Writing data to the slave is done via pulse−width mo
dulation of the clock in accordance with the BiSS B mode" protocol specification
http://www.biss−ic.de/files/BiSS_b3ds.pdf; a directional switch of the data trans
mission line does not take place. Pulse and data are transmitted in RS485 technology,
that is, a signal is not inverted and sent inverted and output at the receiver as a differ
Festo DNCE−...−LAS 1003b English
Cable colour
Designation
n.c.
n.c.
black
Temp 1
black
Temp 1 GND
blue
Ref +
brown
Ref
green
SLO+
yellow
SLO
black
GND
brown
VCC
red
MA
orange
MA+
Function
Pin allocation
reserved
reserved
Temperature
1)
sensor
GND temperature
1)
sensor
Reference switch +
Reference switch
Sensor plug, yellow
2)
Data output +
2)
Data output
GND measuring
system
VCC measuring
system (+5 VDC)
2)
Clock input
2)
Clock input +
Encoder plug, red
5
6
4
4
3
3
1
2
5
6
4
4
3
3
1
2
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dnce las 32Dnce las 40Dnce serie

Tabla de contenido