Installation; Mechanical Assembly - Festo DNCE LAS Serie Instrucciones De Utilizacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
DNCE−...−LAS
5

Installation

Mechanical assembly

Fitting in a vertical or sloping position
Warning
Uncontrolled moving masses can cause injury to people (danger of fingers
being squashed) or damage to property.
S Check whether additional external safety measures are required to prevent
the working load from sliding down.
The DNCE−LAS has no self−locking.
With all applications
Note
The possible dynamics and accuracy of the DNCE−LAS may be reduced
depending on the fitting (stiffness and temperature stress).
S Make sure that the device is fitted free of mechanical stress and distortion
(e. g. by fastening with a fixed bearing and a movable bearing).
S Avoid an accumulation of heat. A high packing density or tight installation
situations cause an accumulation of heat.
S Make sure that the mechanical components (incl. base) are not fitted too
stiffly.
Fasten the DNCE−LAS.
S
Please select the appropriate accessories
S
from our catalogue
www.festo.com/catalogue
Note the maximum permitted tightening
S
torque for the fastening screws of 5 Nm
(M6).
Tighten the screws evenly.
S
28
Fig. 2
Festo DNCE−...−LAS 1003b English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dnce las 32Dnce las 40Dnce serie

Tabla de contenido