hazardous risk of bursting. Check
the manufacturer's maximum
pressure rating for air tools and
accessories. The regulator outlet
pressure must never exceed the
maximum pressure rating.
Compressed air from the unit may
contain wa ter condensation and
oil mist. Do not spray un fil tered air
at an item that could be damaged
by moisture. Some air tools and
accessories may require filtered air.
Read the in struc tions for the air tools
and accessories.
CUSTOMER RESPONSIBILITIES
Procedure
Check safety valve
Inspect air filter
Drain air tank
Check for unusual noise/vibration
Check for air leaks
Clean compressor exterior
Remove tank from service
*
To check for air leaks apply a solution of soapy water around joints. While
compressor is pumping to pressure and after pressure cuts out, look for
air bubbles to form.
1 - more frequent in dusty or humid conditions
2 - For more information, contact a Trained Service Technician.
Too much air
pressure causes a
Risk of unsafe
operation.
MAINTENANCE
how to Start
1.
Turn the Auto/Off switch to
"On/ Auto" and allow tank pres-
sure to build. Motor will stop
when tank pressure reaches "cut-
out" pressure.
2.
Pull the regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.
is noticed, stop the compressor
immediately and have it checked by
a trained service technician.
The compressor is ready for use.
Daily Daily
or after
each use
X
X
X
*
X
X
14- ENG
If any unusual
noise or vibration
Weekly
See tank
warning
label
X
1
X
2