Stage 3: DETERMINE THE ORIGIN OF THE FAULT: XSE TRANSMITTER
OR SAFETY EDGE?
Disconnect the safety edge.
test 1: Press and hold the MODE button for 3 seconds to launch safety
edge detection.
- If LED2 flashes red for 8 seconds then the XSE transmitter is operating
correctly.
- If not, the XSE transmitter is faulty.
test 2 (optional): Press and hold the MODE button for 3 seconds to launch
safety edge detection by short-circuiting the 2 contacts on the ESE J3
connector (using a flat-blade screwdriver).
- If LED2 lights up red for 8 seconds then the XSE transmitter is operating
correctly.
- If not, the XSE transmitter is faulty.
if tests 1 and 2 show that the transmitter is operating correctly, replace
the safety edge.
> Problem waking up the transmitter at the up point
important: For each test, wait until LED2 goes off to test that the transmitter
wakes up.
test 1: Check that the XSE transmitter is working by tapping it and check that
LED2 lights up green. If not, press and hold the PROG button for 3 seconds
and retest. If the problem persists, replace the XSE transmitter.
test 2: Open the door fully, check that a base magnet is fitted and/or that
dipswitch 3 is ON, then retest.
test 3: If the problem persists, fit an upper magnet and set dipswitch 4 on the
XSE transmitter to ON then retest.
If the problem persists, replace the XSE transmitter.

15.3 ese transmitter

Press the button on the inside of the transmitter once.
The transmitter indicator light will come on.
If the indicator light flashes:
6 times → the safety edge is faulty (short-circuit).
8 times → the safety edge has not been correctly lengthened (open circuit).

15.4 ose transmitter

Press the PROG SW4 button on the safety edge transmitter. Press it down until
the indicator light goes out (the indicator light is permanently lit while the button
is pressed).
The transmitter indicator light will illuminate:
- first green to provide information on the assembly configuration
- then red to indicate any faults.
Green ose transmitter light
status
Diagnostics
1 green flash
Operation without
magnet (default)
2 green
Operation with base
flashes
magnet only
3 green
Operation with upper
flashes
magnet only
4 green
Operation with upper
flashes
and base magnets
Copyright © 2014 Somfy SAS. All rights reserved.
actions
Check that there are no magnets
installed on the door runner.
Check that magnet(s) are fitted on
the door runner.
Check that the safety edge
transmitter and the magnet(s) are
installed on the right-hand side of
the door.
Perform the installation with magnet
procedure again.
OSE transmitter indicator light fixed red: transmitter faulty
actions
transmitter
indicator light
status
Open the OSE
LED 1 and LED 2:
transmitter
flash green once
housing.
then flash orange
for 1 to 30 seconds,
Remove
then flash green for 5
and refit the
seconds.
battery
LED 1 and LED 2:
flash orange for 1 to
2 minutes
LED 1 and LED 2
remain off
Open the OSE
LED 1 and LED 2
transmitter
remain off
housing.
Press button
LED 1 and LED 2
SW2 until LED
light up red briefly
1 lights up
permanently
red.
LED 1 lights up
green then LED 2
lights up permanently
green for 8 seconds.

16 - teChniCaL sPeCifiCations

GeneraL sPeCifiCations
Power supply
Electrical insulation
Maximum motor output
Safety fuse for motor and integrated
lighting
Climatic operating conditions
Somfy radio frequency
Number of storable remote controls
ConneCtions
Mains power supply cable
Integrated courtesy lighting
Safety inputs
Self-test output for safety devices
Wired control input
Orange light
Alarm siren output
oPeration
Control buttons
Automatic closing mode
Maintenance assistance
actions
The battery and the transmitter are
operating correctly.
If the problem persists, replace the
battery (part no. 1782078).
The battery is low, replace it (part
no. 1782078).
The OSE transmitter is no longer
operating and must be replaced (ref.
1781245). Follow the instructions
provided with the OSE transmitter
then carry out commissioning as
described in section 5.
Check that the rubber on the safety
edge is not crushed and repeat the
check.
Check the photoelectric sensor
wiring and repeat the check.
If the problem persists, replace
the optical cells by following the
instructions provided with the cells.
Photoelectric sensors:
- for a strip of 3 m max.: ref. 9016767
- for a strip of 7 m max.: ref. 9015560
The OSE transmitter and the
photoelectric sensors are operating
correctly.
If the problem persists, replace the
battery (part no. 1782078).
230 V - 50-60 Hz
Category 1
230 V - 1250 W
5 AT - 250 V - spare fuse supplied
- 20°C/+ 60°C - IP 20
433.42 MHz
32
2 m - IEC sheet (phase-neutral-earth)
E14 - 15W max. - 230V
3 inputs for:
- Wired safety edge: optical, resistive
- Fall protection device
- Photoelectric cells
For cells
NO dry contact - sequential operation
24V - 4W max.
Yes
Up-Stop-Down buttons in the control
panel
Yes
Real time status with 5 indicator lights