Rollixo RTS
Indicator light 2
on the receiver goes out and the receiver Prog
indicator light will flash and then go out (this may take a few seconds,
the time required for the transmitter and receiver to communicate with
each other).
The transmitter is memorised in the receiver.
1
2
3
4
Prog
STOP
4s
1
2
3
4
Prog
STOP
[3]. Optional: the base magnet must be installed if the ground is uneven and
causes erratic obstacle detection.
Press the
button to move the garage door to the bottom position, then
secure the base magnet to the edge of the runner, positioning it in line
with the transmitter.
Move SW3 dipswitch 1 on the transmitter to ON.
This operation is important. Ensure the alignment is observed.
6 - instaLLinG a resistive raDio
safety eDGe With ese transMitter
6.1 installing magnets on the runner
To function correctly, this solution requires a set of magnets to be installed on
the runner.
Copyright © 2014 Somfy SAS. All rights reserved.
1
2
3
4
STOP
Prog
1
2
3
4
STOP
Prog
10 mm maxi.
Base
magnet
ON
1 2 3 4
uPPer magnet
safety edge
transmitter
mounting plate
Base magnet
[1]. Press button
to position the garage door in the upper position.
Ensure the safety edge transmitter is not fixed to its plate.
1
2
3
4
STOP
Prog
[2]. Fix the upper magnet to the edge of the runner observing a distance of
70 mm between the base of the transmitter and the top of the magnet.
1
2
3
4
STOP
Prog
This operation is important. Ensure the dimensions are observed.
1
2
3
4
Prog
STOP
1
2
3
4
Prog
STOP
[3]. Press button
to position the garage door in the low position.
1
2
3
4
Prog
STOP
[4]. Attach the magnet to the edge of the runner, positioning it in line with the
transmitter.
1
2
3
4
Prog
STOP
This operation is important. Ensure the dimensions are observed.
1
2
3
4
Prog
STOP
1
2
3
4
Prog
STOP
[5]. Press button
then stop the door by pressing button
garage door in the intermediate position.
1
2
3
4
STOP
Prog
6.2 installing the resistive safety edge and its ese
transmitter
Follow the instructions provided with the ESE transmitter and the resistive
safety edge lengthening kit.
10 mm maxi.
70 mm
STOP
uPPer
magnet
STOP
10 mm maxi.
Base
magnet
to position the
STOP
STOP
7