oFF
DISPLAY
in 1
PHOTOCELL ACTIVE ONLY DURING CLOSING
The intervention of the photocell during the
opening stage is ignored.
The intervention of the photocell during the
closing stage causes the shutter to reopen.
in 2
PHOTOCELL TEST INACTIVE
The photocell operation test is not
performed
in 3
MECHANICAL SAFETY EDGE
The L6 input is configured to manage a
mechanical safety edge
in 4
FIRE FUNCTION
The L7 input is configured to manage a fire
alarm
in 5
EDGE / FIRE FUNCTION
The L6 input is configured to manage a safety
edge
The L7 input is configured to manage an alarm
ou 1
FLASHING LIGHT
Output (E1 - E2) is on intermittently (2 Hz) during
opening and closing and during pause mode, if
automatic reclosing is active
ou 2
END OF CYCLE NON-ACTIVE SIGNAL
At the end of the operating cycle, the control
unit sends no signal
Lo 1
START/STOP LOGIC
The START/UP input controls the STEP or
AUTOMATIC operational cycle based on the
programmed operational logic.
The DOWN input is inactive
Lo 2
START INACTIVE WHILE OPENING
During opening, the START command
is ignored
Lo 3
STEP LOGIC
The start command activates an
OPEN-STOP-CLOSE-STOP-OPEN
operational cycle
on
PHOTOCELL ACTIVE DURING OPENING AND
CLOSING
The intervention of the photocell during the
opening phase causes the motor to stop.
When the photocell beam is released, the
automation starts during opening for the work
ti1
time set in parameter
.
The intervention of the photocell during the
closing stage causes the shutter to reopen.
PHOTOCELL TEST ACTIVE
Each time the control unit receives an open or
close command, the PHOTOCELL TEST verifies
that the PHOTOCELL is operating correctly.
If the test fails, the display shows
RESISTIVE RUBBER / OPTICAL SAFETY EDGE
The L6 input is configured to manage a safety
edge (resistive rubber / optical) with active
operation test.
If the test fails, the display shows
ALARM FUNCTION
The L7 input is configured to manage an
anti-theft command
LIMIT SWITCH FUNCTION
The L6 input is configured to manage an
opening limit switch
The L6 input is configured to manage a closing
limit switch
in 5
on
NOTE: If
is set
the settings of the
in 4
and
functions, they are not considered
COURTESY LIGHT
The output (E1 - E2) is on and fixed during
opening, pause and closure. Having completed
the operating cycle, the light remains on for the
COURTESY LIGHT OFF DELAY time
END OF CYCLE ACTIVE SIGNAL
At the end of the operating cycle, the control
unit sends a signal to the WES sensors to activate
ENERGY SAVING mode
UP/DOWN LOGIC
The START/UP input always controls opening
and the DOWN input always controls closing,
independently of the operational logic
programmed.
UP + DOWN when pressed simultaneously is the
same as a STOP command
START ACTIVE WHILE OPENING
During opening, the START command
interrupts opening (no timer is set for automatic
re-closure)
AUTOMATIC LOGIC
The start command activates an
OPEN-PAUSE-CLOSE-STOP operational cycle
Closure starts automatically after the pause
time set
14
dEF1 dEF2 dEF3
on
oFF
oFF
oFF
- L5 -
oFF
on
- L6 -
oFF
oFF
oFF
oFF
in 3
oFF
on
oFF
on
oFF
on
on
on
oFF
oFF
oFF
oFF
oFF
oFF
oFF
on
oFF
on
on
oFF