oFF
DISPLAY
Lo 4
DEAD MAN LOGIC INACTIVE
By simply using the start command, the user can
activate the automation device in opening or
closing.
The maximum duration of opening or closing
depends on the operating time set
Lo 5
TIMER FUNCTION
Each time the timer closes the contact L1-L3, the
automation starts during opening and remains
paused until the contact is released.
Lo 6
THE INTERVENTION OF THE SAFETY EDGE
DOES NOT DISABLE AUTOMATIC CLOSING
Lo 7
DEAD MAN LOGIC FROM BUTTON
The dead-man logic can only be activated via
buttons (terminal board and push button panel).
Lo 8
DEAD MAN LOGIC ACTIVATED DURING
OPENING AND CLOSING
Lo 9
PRE-FLASHING NOT ACTIVATED
DISPLAY FUNCTION
ti 1
WORK TIME
ti 2
PAUSE TIME
ti 3
DELAYED TURNING OFF OF THE COURTESY
LIGHTS
on
DEAD MAN LOGIC ACTIVE
The user must press and hold the start button
for the entire duration of the desired opening or
closing procedure.
The maximum duration of opening or closing
depends on the operating time set.
DEAD MAN logic may be implemented with
both Start/Stop and Up/Down logic.
The STOP command interrupts the operational
cycle, independently of the status of the control
inputs.
Hence, if the UP or DOWN button is pressed, the
action of STOP is to stop motion, and on its
release the motor DOES NOT MOVE UNTIL THE
UP or DOWN INPUT IS RELEASED AND PRESSED
ONCE MORE
PLEASE NOTE: when the Man-Present
function is enabled, radio-controlled
operation is disabled. To activate via radio,
Lo 7
on
set the parameter
=
EMERGENCY DEAD-MAN FUNCTION
If a command is rejected because of active safety,
keep the command active for 5 seconds, the
control unit then activates dead-man mode, and
the shutter moves as long as the switch is held.
When the command is suspended, the control
unit returns to the mode set.
This way, it is possible to move the shutter when
there is evidence of a fault on a safety.
THE INTERVENTION OF THE SAFETY
DISABLES AUTOMATIC CLOSING
DEAD MAN LOGIC FROM BUTTON AND
FROM THE TRANSMITTER
The dead-man logic can be activated via buttons
(terminal board and push button panel) and from
the transmitter.
DEAD MAN LOGIC ACTIVATED ONLY DURING
CLOSING
PRE-FLASHING ACTIVATED
Before activating the motor during opening, the
flashing light is turned on for 1 second.
Before activating the motor during closing, the
flashing light is turned on for 3 seconds.
AVAILABLE VALUES
7" - 1 0" - 1 5" - 20" - 30" - 45" - 60"
75" - 90" - 1 20"
1 0" - 1 5" - 20" - 30" - 45" - 60"
90" - 1 20" - 1 80" - 250"
3" - 5" - 1 0" - 20" - 30" - 60"
1 20" - 300" - 600" - 1 200"
15
dEF1 dEF2 dEF3
oFF
oFF
on
oFF
oFF
oFF
on
oFF
oFF
oFF
oFF
on
oFF
oFF
on
oFF
oFF
oFF
dEF1 dEF2 dEF3
20"
30"
30"
30"
1 5"
1 5"
3"
1 20" 1 20"