Current Default Settings; Training Stand-By; Performance (Fixed) - Kettler SG1 Instrucciones De Entrenamiento Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

b) Performance profiles
2. Training according to pulse default settings
a) Manual pulse input
b) Pulse profiles
1a
Selecting a training programme by means of manual perfor-
mance input e.g. "Count Down"
By pressing "Presets" you will skip to the menu "Current
default settings". The menu displays the default settings, which
are to be entered or have already been entered at the "active
programme".
Performance (manual) –> Current default set-
tings
In this menu, you can view, change or maintain the default
settings for the active programme.
Display:

Current default settings

The default settings are the values, which the active user
"Thomas" entered beforehand under Default Settings –>
Training values and pulse default settings:
Energy consumption
Training time
Workout distance
Maximum pulse (selected)
Alarm at exceeding the maximum pulse
Target pulse monitoring
Fitness (75%)
By pressing "Training" you will adopt the values and settings
and you skip to the view "Training stand-by"

Training stand-by

This image illustrates values and settings
Display :
Top
Current pedal rate = 0 min -1
Current speed = 0.0 km/h
The following was taken over from "Thomas'" presets: wor-
kout distance = 7.50 km
Duration of work out = 30:00 min
Energy consumption = 800 kJoule
Current performance ratio = 4 % (current performance to
set maximum performance 600 watt.) preset performance
= 25 watt
Current pulse = 70 bpm [beats/min] Current pulse ratio =
41% (current pulse to maximum pulse)
Display:
Bottom
Active person = Thomas
Programme symbol
Current date and time
Active programme = perform. (manual) Count Down
Press "Menu" to jump back.
Press "User" to jump back to the "Users" menu
Press "Presets" to jump to the "Current Presettings" menu to
=
800 kJoule
display the presettings that yet need to be or have already
=
30 min
been entered in "active" programmes.
=
7.50 km
Note:
=
170 bpm
=
on
The performance can be increased or decreased by 25 Watt
=
on
by means of the navigation keys or by 5 Watt by means of
=
active
the –/+ keys during training stand-by or training
1b
Selecting a training programme with performance profile: e.g.
Performance (fixed) Programme 1"
By pressing "Presets", you will skip to the menu "Current
Default Settings" and the default settings, which are to be
entered or which have already been entered at the "active"
programme are displayed.
Display : Current default settings
Mode
Programme length
Max. pulse (selected)
Alarm at exceeding the maximum pulse =
Here the default settings are the values, which the active user
"Thomas" entered beforehand under Default Settings –> Pulse
default settings:
Programme Mode Time or Distance
Pressing "- /+" will switch the mode of the programme from
time to distance. Under programme length, you can adjust the
time from 20 - 90 minutes and the distance from 8 kilometres
to 36 kilometres (cross ergometer 4 - 18 kilometres).
Display:
Current default settings
Mode
=
time
=
30 min
=
170 bpm
on
=
Distance
7
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sg4Ergorace sg1

Tabla de contenido