oPeration witH PortaBle generator

WARNING: Before operating
heater or any appliance from a
portable generator, verify that
generator has been properly con-
nected to earth ground. Improper
grounding or failure to ground
generator can result in electro-
cution if a ground fault occurs.
Refer to owner's manual supplied
by generator manufacturer for
proper grounding procedures.
Operating voltage range of heater is 108 to
132 Volts (120 Volts +/- 10%). Prior to plug-
ging heater into generator output voltage
should be verified (if generator is equipped
with automatic idle feature, output voltage
should be measured with generator running

Storing, tranSPorting or SHiPPing

Note: If shipping, transport companies require
fuel tanks to be empty.
1. Remove excess fuel from tank using a si-
phon pump. Drain remaining fuel through
filler neck by tipping heater on its side.
2. If any debris is noted in old fuel, add 1 or 2
quarts of clean kerosene to tank, stir and
drain again. This will prevent excess debris
from clogging filters during future use.

PreVentatiVe maintenanCe SCHedule

WARNING: Never service heater while it is plugged in, operating
or hot. Severe burns and electrical shock can occur.
Item
Fuel tank
Air output and lint filters
Air intake filter
Fuel filter
Spark Ignitor
Fan blades
Motor
10

How Often

Clean every season or as needed
Replace every 500 hours of operation
or once a year
Wash and dry with soap and water every
500 hours of operation or as needed
Clean twice a heating season or as
needed
Clean and regap every 500 hours of
operation or replace as needed
Clean every season or as needed
Not required/permanently lubricated
www.desatech.com
at full speed). If voltage does not measure in
this range heater should not be plugged into
generator.
Refer to Operation, page 8, for starting, stop-
ping and resetting heater procedures.
Alternator
Ground Wire (#10 AWG
- Stranded-Copper)
Figure 15 - Typical Generator Grounding
Method (Generator construction may
vary from that shown)
3. Properly dispose of old and dirty fuel.
Check with local automotive service sta-
tions that recycle oil.
4. If storing, store heater in dry place. Make
sure storage place is free of dust and
corrosive fumes.
IMPORTANT: Do not store kerosene over
summer months for use during next heat-
ing season. Using old fuel could damage
heater.
How To
See Storing, Transporting,
or Shipping
See Air Output, Air Intake
and Lint Filters, page 14
See Air Output, Air Intake
and Lint Filters, page 14
See Fuel Filter, page 15
See Spark Ignitor, page 15
See Fan, page 13
Ground Lug
Copper
or Brass
Grounding
Point
118419-01D