Wiring Diagram - Desa TA100 Manual Del Propietário

Calentadores portátiles de aire forzado calentador de keroseno/diesel con termostato incorporado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10. Adjust pump pressure (see Pump Pres-
sure Adjustment, page 14).
Note: If rotor is still binding, proceed as
follows.
11. Perform steps 1 through 6.
12. Place fine grade sandpaper (600 grit) on
flat surface. Sand rotor lightly in "figure 8"
motion four times (see Figure 33).
13. Reinstall insert and rotor.
14. Perform steps 8 through 10, page 17.
Blue
Photocell
Blue
Black
Thermistor
Black
Blue Side
of Metal
Conductors
18
SerViCe ProCedureS
Continued

wiring diagram

C
O
N
T
R
O
L
Thermostat
Touch Pad
www.desatech.com
Blade
Figure 32 - Gap Adjusting Screw
Sandpaper
Figure 33 - Sanding Rotor
Red
High
Voltage
White
Ignitor
Red
Motor
White
Black
Black
Green
White
White
On/Off
Switch
Gap Adjusting Screw
0.003"/0.004"
(0.076-0.101 mm)
Gap Measured
With Feeler
Gauge
Rotor
Gap Adjusting Screw
Locations
Spark
Black
Ignitor
Green
Green
Power Plug
120V/60HZ
118419-01D