DSC SHOCKGARD SS-102 Guia Del Usuario

DSC SHOCKGARD SS-102 Guia Del Usuario

Publicidad

Enlaces rápidos

3301 Langstaff Road
SHOCKGARD SS-102 - Installation Instructions - English
Concord, Ontario, Canada
L4K 4L2
Tel: (905) 760 3000
www.dsc.com
DESCRIPTION
The Shockgard SS-102 electronic shock sensors have been designed utilizing the most advanced microchip technology to provide
reliable effective false alarm resistant protection.
The Shockgard SS-102 series offers a wide range of features including remote LED reset, first to latch indication and subsequent to alarm latch
information. Other features include automatic relay reset and dual stage linear sensitivity adjustment by selection offering a broad band
of sensitivity control. Selectable pulse count and dual colour LED information provides the installer with everything he requires for this
type of detector.
Alarm output is provided by a pair of non-latching, normally closed relay contacts, opening for a minimum of 1 second on detection of an
alarm. This relay is normally energized to give fail-safe operation in the event of a power loss.
Indication is provided by a LED situated on the front cover. On board circuitry allows for the selection of momentary or latching indication.
An automatic LED inhibit feature is also included. Latch enable and reset may be remotely controlled by standard control panel signals.
The unit is fully protected from tampering by a N.C. switch operated by removal of the cover. Moisture repelling rubber grommets are
provided with the Shockgards.
CONNECTION Refer to Fig. 1
Terminals
1(+) 2(-)
12V power connection, reverse polarity protected.
3 4
N.C. Alarm output contacts, with 10 ohm resistor in series.
5A / T6
N.C. Anti-tamper contacts.
7
Connection for +12V remote latch control signal, usually SET+ or SW+ control equipment signal.
4
Fig. 1
1
2
3
11
5
S2
1
2
3
4
5A / T6
7
-
+
Sensor
1
2
3
4
5
6
OFF
MIN
MAX
9
8 7 6
10
When using the sensor in momentary mode, it will usually be necessary to connect using a 6 core cable. If the latch facility is being used
an additional core will be required for the connection of the latch terminal.
MODES OF OPERATION
In all modes of operation the N.C. alarm contacts are non-latching. Upon alarm activation the alarm contacts will open circuit momentarily for a
minimum time of 1 second before automatically resetting.
Momentary - latch terminal unconnected.
The LED will illuminate when the alarm contacts are open circuit in response to an input signal.
LED Indication - During the sensitivity test procedure, indication of the green LED denotes alarm and relay operation. Indication of the red LED
denotes vibration detected (pulse) but insufficient to create alarm conditions.
Dual stage linear sensitivity - The detector permits the installer a greater threshold of sensitivity adjustment by selection.
Adjustment of the potentiometer through either a low level or high level adjustment. When DIP Switch 5 is in the On positition the
sensitivity potentiometer allows adjustment in the high sensitivity area and when in the Off position the sensitivity potentiometer allows
adjustment in the low sensitivity area.
Latching - 12V applied to latch terminal. When 12V is applied to the latch terminal the LED is inhibited. Upon removal of the 12V signal the LED
will indicate the status of the latch, i.e. if the unit has detected an alarm the LED will be permanently flashing amber otherwise the LED will
operate in momentary mode. Reapplication of the 12V signal will reset the latch and extinguish the LED.
First to Latch - 12V applied to latch terminal via a 47k resistor. See fig. 2. Operates as in latching mode with the exception that only the
first unit to detect an alarm will latch, with a flashing LED. Any subsequent detector to alarm will indicate with a steady LED.
Latch operation 6 wire - Should the Shockgard SS-102 be wired in a 6 wire configuration, latch reset can be achieved by selection of the
fourth switch of the DIP Switch unit. With this switch in the 'ON' position, and the Shockgard SS-102 activated in full alarm, the LED will
latch on with the LED flashing amber until the supply voltage is interrupted when the Shockgard SS-102 will reset.
Alternative latch reset can be achieved by using a seven wire configuration with the latch reset wire connected with terminal 7 on the
main terminal block.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This Class B digital apparatus meets all requirements of the ICES-003.
Cet appareil numérique de la classe B respecte toutes les exigences du ICES-003.
5IN06050 D
端子
12V电源连接端子,具有反极性保护功能。
1(+) 2(-)
常闭警报输出触点,配备10欧姆电阻。
3 4
常闭防拆输出触点。
5A / T6
+12V远程锁存控制信号连接端子,通常使用SET+或SW+控制设备信号
7
4
Fig. 1
1
2
3
11
5
S2
1
2
3
4
5A / T6
7
-
+
Sensor
1
2
3
4
5
6
OFF
MIN
MAX
10
9
8 7 6
6
Fig. 1
1) 12V
2) 0V
3) ALARM CIRCUIT
4) LATCH TERMINAL (12V SET + SW +)
5) ANTI TAMPER
6) NOT USED
7) SENSITIVITY SELECTION LEVEL (Low/High)
8) LATCH RESET SWITCH
9) PULSE COUNT SELECTION SWITCHES
10) SENSITIVITY ADJUSTMENT
11) ANTI TAMPER SWITCH
Fig. 1
1) 12V
2) 0V
3) 警报电路
4) 锁存端子(12V SET+ SW+)
5) 防拆
6) 备用
7) 灵敏度调节(低/高)
8) 锁存复位开关
9) 脉冲计数选择开关
10) 灵敏度调节旋钮
11) 防拆开关
Pulse count and latch operation
A series of 6 switches are situated below the main terminal block for pulse count selection, sensitivity selection and operation of latch when
using a six wire configuration. The first three switches, i.e.. 1, 2 and 3 are designated for pulse count. Selection as follows:
A. For pulse count two. Switch No. 1 to 'ON' position. Switches 2 and 3 to 'OFF'.
B. For pulse count four. Switch No. 2 to 'ON' position. Switches 1 and 3 'OFF'.
C. For pulse count six. Switch No. 3 to 'ON' position. Switches 1 and 2 'OFF'.
D. For no pulse count. Switches 1, 2, and 3 in off position.
Switch 4: See Latch Operation 6 Wire paragraph.
Switch 5: Enables Sensitivity adjustment - 'ON' - High, 'OFF' - Low.
Switch 6: Not used.
Testing prosedure of pulse count
After selection of number pulse counts required and adjustment of sensitivity level, tap the area of coverage allowing a few seconds between each
tap. After each tap, the LED will indicate red colour mode, confirming receipt of vibration and pulse received, On completion of pulses selected, the
Shockgard SS-102 will activate the relay and the LED will confirm activation by illumination of a green LED. In the event of gross attack, the
unit will disregard the pulse count memory and activate the relay and illuminate green LED indication.
INSTALLATION PROCEDURE
1. Select the intended position for installation, ensuring the surface is clean and clear of any irregularities.
2. Remove the cover of the sensor by unscrewing the single captive screw, until the cover can easily be removed from the base.
3. Carefully lift the printed circuit board from the base.
4. Present the base to the mounting position and mark the desired fixing holes.
5. If rear cable entry is required, cables should be threaded through the rear of the base.
6. Fix the base in position using the screws provided, or pin nails if preferred (some hard surfaces may require pilot drilling).
7. Carefully push the printed circuit board onto the base.
8. Make the electrical connections to the Shockgard SS-102.
9. If side cable entry is being used, remove the appropriate knockout from the cover and put in a grommet.
10. Setting up and adjustment: With the unit in momentary operation, (See modes of operation. Dual stage linear sensitivity). Use a terminal screw-
driver to turn the sensitivity control (See fig. 1) fully clockwise to maximum (Position 6). Using a suitable implement, bang or tap the protected
area, observing the LED response. Reduce the sensitivity by a small amount (turn sensitivity control anti-clockwise) and bang or tap the protec-
ted area. Repeat this process until the unit only just responds to the desired impact.
11. Replace the cover of the sensor, tighten the fixing screw and check its response to the desired impact.
Multiple Unit Connection Procedure
Fig. 2
DO NOT FIT THIS RESISTOR IF USING ANY TO LATCH
12 VOLT
SWITCH
0 VOLTS
12 VOLT
ALARM
OUTPUT
ANTI
TAMPER
DETECTION RANGE
Surface
Brick Wall
Steel
Wood
Radius
2.5 m
3 m
3.5 m
) All values quoted are typical and are subject to practical testing which must be made for each installation. In some environments,
attenuation may be very high.
TECHNICAL DATA
SS-102
Supply Voltage
9V-16V DC
Current - quiescent
15mA maximum
- alarm
16mA maximum flashing LED 27mA
Temperature limit
-20ºC to +60ºC
Relative humidity at 30ºC
0-90%
Sensitivity setting
Dual stage potentiometer
Latching / Non Latching
1st + subsequent or any + 6 wire
Indicator
Two colour LED
Dimensions (mm)
25 x 23 x 85mm
Relay Contact Rating
150mA 24V resistive 10 Ohm 1/4 Watt
Time relay open in alarm
1 second minimum
Pulse count
2, 4 or 6
Max. No. of units on any Latch
80
Max. No. of units on 1st to Latch
10
开关 4:详见6线锁存操作说明
开关 5:灵敏度水平调节-ON-高, ' OFF' -低
开关 6:备用
Shockgard SS-102
探测范围 *
防护表面
砖墙
木质
半径
2.5 m
3 m
3.5 m
*) 以上所引用的数值均是典型值,每次安装后都必须做实际测试,并以实际测得的数值为准。在某些情况下,可能会有很高衰减。
Concrete
Plywood
Gyproc
Glass
1.5 m
4 m
2.5 m
3.5 m
SHOCKGARD SS-102 Made in Israel
混凝土
复合板
石膏板
玻璃
1.5 m
4 m
2.5 m
3.5 m

Publicidad

loading

Resumen de contenidos para DSC SHOCKGARD SS-102

  • Página 1 This relay is normally energized to give fail-safe operation in the event of a power loss. Shockgard SS-102 will activate the relay and the LED will confirm activation by illumination of a green LED. In the event of gross attack, the Indication is provided by a LED situated on the front cover.