Technical data
Operating voltage
Max. current consumption
DI voltage
Max. pull-up resistance at DI
Operating temperature
Protection class
Storage temperature
Max. humidity
Digital inputs
Interface
Min. transmission pause:
- between two state changes
- with a triggered lifestyle 17
Power supply unit
Transmitter
Max. cable length
12 V AC / V DC ±20 %
40 mA (AC), 20 mA (DC)
12 V AC / V DC ±20 %
100 kΩ (DC)
0...40 °C
IP 20
–20 °C...+70 °C
95 %, non-condensing
5
X-10
10 seconds
approx. 1 minute
HN 10
868.3 MHz
30 m
Technical data
69