ASSEMBLY

(FOR 110/115/155/165/200 MODELS
ONLY)
These models are furnished with wheels and a rear
handle. Some models are furnished with a front
handle also. Wheels, handle(s), and the mounting
hardware are found in the shipping carton.
Tools Needed
• Medium Phillips Screwdriver
• 3/8" Open or Adjustable Wrench
• Hammer
1. Slide axle through wheel support frame. In-
stall wheels on axle.
IMPORTANT: When installing wheels, point
extended hub of wheels toward wheel support
frame (see Figure 5).
2. Place cap nuts on axle ends. Gently tap with
hammer to secure.
3. Place heater on wheel support frame. Make
sure hot air outlet end (front) of heater is over
wheels. Line up holes on fuel tank flange with
holes on wheel support frame.
4. Place rear handle (and front handle if pro-
vided) on top of fuel tank flange. Insert screws
through handle(s), fuel tank flange, and wheel
support frame. Attach nut finger tight after
each screw is inserted.
5. After all screws are inserted, tighten nuts
firmly.
Screw
Hot Air
Outlet
Fuel Tank
Flange
Wheel
Support
Frame
Nut
Cap
Wheel
Nut
Figure 5 - Wheel and Handle Assembly,
110/115/155/165/200 Models Only
114008-01A
Front Handle
Handle
(If Provided)
Air
Inlet
Extended
Hub
Axle
www.desatech.com

OPERATION

IMPORTANT: Review and under-
stand the warnings in the Safety
Information section, page 2. They
are needed to safely operate this
heater. Follow all local ordinances
and codes when using this heater.
TO START HEATER
1. Follow all ventilation and safety information.
2. Locate heater to provide maximum circulation
of the heated air. Follow all location require-
ments noted in Safety Information, page 2.
3. Fill fuel tank with fuel. Use only kerosene,
#1/#2 diesel/fuel oil, JET A or JP-8 fuels to
avoid risk of fire or explosion. Never use gaso-
line, naphtha, paint thinners, alcohol, or other
flammable fuels.
4. Attach fuel cap/gauge.
5. Plug heater's power cord into approved,
grounded, three-wire extension cord. Extension
cord must be at least six feet (1.8 meters) long.
Extension Cord Size Requirement
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG
2
(0.75 mm
) rated cord
11 to 100 feet (3.3 to 30.5 meters) long, use
16 AWG (1.0 mm
101 to 200 feet (30.8 to 61 meters) long, use
14 AWG (1.5 mm
6. Plug extension cord into standard 120 volt/60
hertz, 3-prong grounded outlet.
7. Turn thermostat knob to the right (clockwise)
to the warmest position.
8. Push ON/OFF switch to the ON (|) position.
Light will come on. Note: Ignitor will pre-
heat for five seconds, then heater will start.
9. After heater is running, adjust thermostat knob
to the desired setting. Note: A cold heater may
affect the thermostat setting. This thermostat
is a general-heating control. It is not intended
for precise temperature control. Adjust thermo-
stat until heater cycles at the desired setting.
TO STOP HEATER
Push ON/OFF switch to the OFF (O) position.
TO RESET HEATER
1. Push ON/OFF switch to the OFF (O) position
and wait 10 seconds. (Wait two minutes if
heater has been running.)
2. Repeat steps under To Start Heater.
2