Technical Data; Order Numbers - Brita purity 450 Quell ST Instrucciones De Sustitución

Ocultar thumbs Ver también para purity 450 Quell ST:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Check system for any leaks.
Write the next replacement date on the sticker supplied and affix this to the service pass on the
pressure vessel
Note: Do not stick over the top sticker with the installation date.
Note: Filter systems without measuring and display units are now ready for operation.
Checking initialisation of filter systems with a measuring and display unit
The carbonate hardness, bypass setting as a percentage, remaining capacity in litres and the
current date must be shown on the display (Manual Chapter 5.5).
Note: If these values are not shown on the display the filter system must be flushed again
(Manual Chapter 5.4), until the values appear on the display.
Note: Filter systems without measuring and display units are now ready for operation.
8 Filter capacity
The filter capacity tables for coffee and expresso machines and vending machines and for combi
ovens and traditional ovens are listed on pages 5/6.
Note: The capacities specified in the bypass and capacity table for coffee and expresso machines
and vending machines are guidelines only that may vary by ± 5 % depending on the product volume
flow and also depending on the type of machine. With combi ovens and traditional ovens, depending
EN
on the type of machine, select the bypass setting 10 % for optimally prepared water for the combi
oven/conventional oven. We will be happy to discuss your individual recommendations.
Note: The capacity limits refer to average use of the appliance, do not contain any filter flushing and
cleaning cycles and depend on local water quality, flow, mains pressure and flow continuity.

9 Technical data

Operating pressure
Operating/water temperature
Ambient temperature during: Operation
Ambient temperature during: Storage

10 Order numbers

Caution: The PURITY replacement cartridge may only be used in combination with the pressure
!
vessel that has been specifically designed for its size. See page 3.
PURITY 450 Quell ST filter cartridge
PURITY 600 Quell ST filter cartridge
PURITY 1200 Quell ST filter cartridge
14
Close flush valve
9
.
1
.
2 bar to max. 6.9 bar
4 °C to 30 °C
10 °C to 40 °C
–20 °C to 50 °C
Article number
273000
273200
273400

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Purity 600 quell stPurity 1200 quell st27300273200273400

Tabla de contenido