Application
Single-hole mixer suitable for:
• direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Operation with unpressurised storage heaters
(= displacement water heaters) is not possible.
Safety notes
• Installation is only possible in frost-free rooms.
• The switched-mode power supply is only suitable
for indoor use.
• In the case of damage to the external connection cable
of the power supply unit, it must be replaced by the
manufacturer or the manufacturer's customer service
department or an equally qualified person, in order to
prevent a hazard.
• The switched-mode power supply connector must not
be directly or indirectly sprayed with water for cleaning
purposes.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty.
Technical data
• Max. flow:
0.8 L/cycle or 0.2 gpc / 0.41 MPa (60 psi)
• Flow pressure:
- min.
- recommended
0.1 - 0.5 MPa (14.5 - 72.5 psi)
If static pressures exceed 0.5 MPa (72.5 psi), a pressure-
reducing valve must be installed.
• Operating pressure
• Test pressure
• Hot water supply temperature:
Recommended (energy economy):
Fitting with battery:
• Voltage supply:
6V lithium battery type CR-P2
Fitting with switched-mode power supply (42 464):
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
• Automatic safety shut-off
(5 - 160 s adjustable):
• Run-on time (0 - 11 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (adjustable):
• Type of fitting protection:
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
1
English
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system.
Additional instructions regarding programme
overview, programme selection and activation of
the functions can be downloaded under
www.grohe.com/tpi/euroeco-ce.
Special accessories
Further settings and special functions are available
via the infrared remote control (Prod. No. 36 206).
Installation
Flush piping system prior and after installation of faucet
thoroughly!
Fitting
Refer to the dimensional drawing and Fig. [1] on fold-out page I.
0.05 MPa (7.25 psi)
Fasten fitting to wash basin, see Figs. [2] and [3].
Connection
1. Attach solenoid valve to nipple, assemble two-piece clip at
max. 1 MPa (145 psi)
the connection point and engage, see Fig. [4].
1.6 MPa (232 psi)
2. Attach solenoid valve to the connection hose, see Fig. [5].
max. 158 °F
3. Connect adapter to the service valve, see fold-out page II,
140 °F
Fig. [6].
4. Install filter in nipple, see Fig. [7].
5. Install solenoid valve via nipple on the adapter, ensuring that
no installation forces are applied to the solenoid valve.
6. Connect solenoid valve cable to electronics cable,
see Fig. [8].
2.4 W
Connecting the voltage supply, see Fig. [9] or [10].
11 s
1 s
Open water supply and check connections for
watertightness.
approx. 5"
IP 59K
Operation
A
The infrared electronics emit invisible, pulsed light.
2
The sensor system is adjusted so that water flow is
2500 V
initiated when the hands approach the vicinity of the spout.
100 °C
When the hands are withdrawn from the vicinity of the
spout, water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 11 s (factory setting) of continuous detection of an object,
the infrared electronics automatically stop the water flow.
activatable
readable
activatable
deactivated
3.5 min