Input
Output
Output signal
Operating conditions
Ambient conditions
Ambient temperature
Note
Pressure transmitter
Storage temperature
Degree of protection
Electromagnetic compatibility
Interference emission and
interference immunity
Permitted pressures
Medium conditions
Process temperature
Measuring cell with silicone oil
filling
Mechanical design
Material
Wetted parts materials
Seal diaphragm
Process connection and locking
screw
O-ring
Non-wetted parts materials
28
6.25 ... 1250 mbar
(2.51 ... 502 inH
2
0.032 ... 6.25 bar
(12.54 ... 2509 inH
0.16 ... 32 bar
(2.33 ... 465 psi)
4 ... 20 mA, with modulated HART signal
Observe the temperature class in hazardous areas.
-40 ... +85 °C (-40 ... 185 °F)
Display not legible: -40 ... -20 °C (-40 ...-4 °F)
Display legible: -20 ... +85 °C (-4 ... +185 °F)
-50 ... +90 °C (-58 ... 194 °F)
IP66/IP68 and NEMA 4x (with appropriate cable gland)
As per EN 61326 and NAMUR NE 21
As per 97/23/EC Pressure Equipment Directive
-40 ... +125 °C (-40 ... 257 °F)
(Note that there is no medium flow through the pressure caps during normal
operation at a temperature > 100 °C.)
Stainless steel, mat. no. 1.4404/316L
Hastelloy C276
Monel 400
PN 160: Stainless steel, mat. no. 1.4404/316L
Standard: Viton [FKM, (FPM)]
Optional:
NBR
PTFE (virginal)
PTFE (glass-fiber reinforced)
FFPM (Kalrez)
Graphite
O)
O)
2
SITRANS P500 with HART
A5E02344532-04, 12/2014