WARNING
Electrostatic charge
Danger of explosion in hazardous areas if electrostatic charges develop, for example, when cleaning plastic enclosures
with a dry cloth.
Prevent electrostatic charging in hazardous areas.
6.3.1

Servicing the remote seal measuring system

The remote seal measuring system usually does not need servicing.
If the mediums are contaminated, viscous or crystallized, it could be necessary to clean the diaphragm from time to time.
Use only a suitable solvent to remove the deposits from the diaphragm. Do not use corrosive cleaning agents. Prevent the
diaphragm from getting damaged due to sharp-edged tools.
NOTICE
Improper cleaning of diaphragm
Device damage. The diaphragm can be damaged.
Do not use sharp or hard objects to clean the diaphragm.
6.4

Return procedure

Enclose the bill of lading, return document and decontamination certificate in a clear plastic pouch and attach it firmly to the
outside of the packaging. Any devices/replacement parts which are returned without a decontamination declaration will be
cleaned at your expense before further processing. For further details refer to the operating instructions.
6.5
Disposal
Note
Special disposal required
The device includes components that require special disposal.
Dispose of the device properly and environmentally through a local waste disposal contractor.
7

Technical data

7.1
General
Input
Measuring span (continuously adjustable)
SITRANS P500 with HART
A5E02344532-04, 12/2014
Devices identified by this symbol may not be disposed of in the municipal waste
disposal services under observance of the Directive 2002/96/EC on waste electronic
and electrical equipment (WEEE).
They can be returned to the supplier within the EC or to a locally approved disposal
service. Observe the specific regulations valid in your country.
Measuring span
1 ... 50 mbar
(0,4 ... 20 inH
O)
2
1.25 ... 250 mbar
(0.5 ... 100 inH
Maximum operating pressure MAWP
(PS)
160 bar (2320 psi)
O)
2
27