Product Data; Technical Data; Scope Of Delivery - Wilo CO-HELIX-V 4 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
The pipes will not withstand loads and should
not be used to secure loads in transit. Some sti-
ckers on manifolds reminds this advice (Fig. 2b).
ATTENTION! Loading the pipes in transit can result
in leaks.
• When the product is delivered, check it for any
damage in transit. If any defect is found, inform the
delivery company (forwarding agent).
The pumps transport lock (if equipped) should be
removed before the start o the pump (sticker Fig. 2c,
2d).
ATTENTION! If the product is installed later on,
store it in a dry place. Protect it from impacts and
any outside influences (moisture, frost, etc. ...).
Handle the product with care.
4. Application
The booster is designed for boosting and maintaining
the pressure when the water supply network is not
well dimensioned or does not exist.
When a speed converter is integrated in the pumps,
the electronic regulation system integrated in the
control unit allows to get a constant pressure in the
water supply network whatever the flow is.
The booster is either or supplied:
- On load: from the public water mains or from a
mains collection tank.
- On suction: (on demand).
WILO SE 01/2012

5. Product data

5.1 Type key
CO-2 HELIX-V 2205/2-5,5/K/CC-03
CO = Standard version
COR = Standard version
with variable speed
Operating mode of the
boosting system:
2 = 2 pumps in cascade
3 = 3 pumps in cascade
4 = pumps in cascade
Pump reference
Pump type:
V = vertical standard pump
VE = vertical electronic pump
Nominal flow (22 m
/h)
3
and number of stages per pump
Total number of impellers/pumps
Motor power when there is 2 motor po-
wers for the same number of pump stages
Pump with cartrige
Control unit:
NO: Without
CE: electronic control
CC: automation control
VR: control for electronic pump
Variant of construction:
03: Manifolds Stainless steel 304 –
assembling glued
04: Manifolds Stainless steel 304 –
assembling in flange
05: Manifolds Stainless steel 304 –
assembling glued – in suction
06: Manifolds Stainless steel 304 –
assembling in flange – in suction

5.2 Technical data

• Max. operating pressure:
• Max. water temperature:
• Max. ambiant temperature:
• Three-phase voltage:

5.3 Scope of delivery

• Booster.
• Control box or cabinet (separate from the booster
set according to the type and power).
• Installation instructions: booster, pump and auto-
matism.
• Safety instruction.
5.4 Accessories (compulsory).
• Diaphragm pressure tank must be sized according
to installation.
• Dry running sensor:
English
16 or 25 bars
+70 °C
+40 °C
50 Hz 230/400V
60 Hz 220/380V –
230/400V (option)
17

Publicidad

Tabla de contenido
loading

Tabla de contenido