General Information; Product Data; Rating Plate - Wilo TP 50 Serie Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
ENGLISH

1 General Information

Assembly and installation should only be carried out by
qualified personnel
1.1 Uses
The submersible motor-driven pumps of the Wilo-Drain TP and
TS series are suitable for removing dirty water/sewage, mud
and clear fluids containing solids of max. 44 mm Ø (TP) or
10 mm Ø (TS) from shafts, pits and vessels. They are used
– for building and surface dewatering,
– in sewage and water-management,
– in environmental and domestic waste disposal,
– in industrial and process engineering.

1.2 Product data

1.2.1 Rating plate

Series:
TP=Submersible motor-driven pump,
TS=Sub. motor-driven pump-drainage water,
Nominal width: TP: 50, 65 [mm]
TS: 40 f Rp 1|
50 f Rp 2
65 f Rp 2|
Type of impeller: TP: E = Single channel impeller
F = Non-chokable impeller (VORTEX)
TS: H = half-open impeller
Diameter of impeller
Special model steel 1.4435
Power P2 [kW] = Value/10
Current type: 1 f alternating current (EM)
3 f three-phase current (DM)
Model „A", ready for connection with 10 m connecting
cable with plug (EEC / earthing pin) and float switch
Manufacturer's key
1.2.2 Connection and electrical data
– Permissible components of the flow media:
– Mildly acidic / mildly alkaline,
– Chloride content max. 150 mg/l (for 1.4301),
– Permission for the transport of waste water containing che-
micals should be obtained from WILO.
– max. permissible grain size (completely free passage):
– Power supply
– Mains frequency:
– System of protection:
– Explosion protection:
– Speed:
– max. power input:
– Admission output P1:
– Motor-output P2:
– max. capacity:
– Delivery head max.
– Operating mode (optimum): Intermittent service S3, 25%
– Operating mode S1:
8
400 mg/l (for 1.4435)
TP f 44 mm
TS f 10 mm
3 ~ 230 V
±10 %
1 ~ 230 V
±10%
50 or 60 Hz
IP 68
EEx d II B T4 without explosion
protection for model „A"
max. 2900 tr/min
see rating plate
see rating plate
see rating plate
see rating plate
see rating plate
(2.5 min. mode, 7.5 min. break).
200 operating hours a year
The pumps are made from stainless steel (1.4301).
TP pumps, for pumping aggressive fluids such as condensa-
tes, partly demineralised and distilled water, in steel grade
1.4435 on request.
The submersible motor-driven pump is normally submerged by
the flow medium. They can be installed stationary or transpor-
table, but only vertically.
TS pumps may not be used to pump raw sewage con-
taining faeces, and TP pumps only on a limited basis.
Local regulations must be observed.
The pump must not be used for pumping drinking
water.
– recommended operating
frequency:
– max. operating frequency: TS40-TP50: 70 1/h;
– Nominal width of
pipe mount:
– Temperature range of the
flow medium:
– Max. immersion depth:
– Oil filling:
Current type
power of motor
190 ml
Oil filling
150 ml
115 ml
TP 65 E 114 X / 11 - 1 / A / XX
TS 40 H 90
/5,5 - 1 / A / XX
20 1/h
TS50: 50 1/h;
TS65-TP65: 40 1/h
see rating plate
+3 to 35°C
10 m
ELFOLNA DS 22 or
comparable.
1~
3~
P2 [kW]
1,5
2,2
≤ 1,5
1,1
≤ 0,75

Publicidad