Novoferm N-563 S Manual De Instrucciones página 45

Ocultar thumbs Ver también para N-563 S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3. Press the programming button (PROG button) (D).
The display shows "8".
Menu 8:
Door adjustments
1. Select menu item "8".
After about 2 seconds the display blinks and the set value time appears.
At delivery, the factory setting is '4'.
For optimal movement and to maintain the forces, the corresponding door type must be selected.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Menu value
0
1
2
3
4
5
6
7
8
9
3. Press the SAVE button (D).
The display shows "9".
Menu 9:
Adjustment other operating modes
1. Select menu item "9".
After approximately 2 seconds, the display flashes and shows the set value of the operating mode.
The factory setting is "0"
N-563 S
Door type
Double swing gate
Non-swinging door, Canopy
Swing door, Kipptor normal
Swing door, tilt sensitive running
Universal setting (factory)
Sectional door with tension spring fitting (Topspeed)
Sectional door with torsion spring fitting (Topspeed)
Industrial door with standard fittings
Side section door (Topspeed)
Side section door with secondary closing edge
Installation
45

Publicidad

Tabla de contenido
loading

Tabla de contenido