Wiring/Configuration-NEMA 1
SubDrive75, SubDrive100, SubDrive150, MonoDrive & MonoDriveXT
To operate a different pump size, a Configuration Switch (SW1) must be positioned to select the correct pump rating .
Reference the chart below for appropriate Configuration Switch setting .
Feed the pressure sensor wires
through the small enclosure
opening and securely attach to the
sensor terminals.
Configuration Switch SW1
MonoDrive
1/2 hp (motor)
MonoDrive
3/4 hp (motor)*
MonoDrive
1 hp (motor)
*(default)
4
3
2
4
3
2
8
From Power Source
L2
L2
L1
(Input)
Sensor
Connection
Black
Red
Power Supply from
Circuit Breaker
Feed the 230 V power leads through the large
enclosure opening and securely attach to the
terminals marked L1, GND and L2.
MonoDriveXT
SubDrive75
1 .5 hp (motor)*
3/4 hp (pump)*
MonoDriveXT
SubDrive75
N/A
1 hp (pump)
MonoDriveXT
SubDrive75
2 hp (motor)
1 .5 hp (pump)
#3 Switch
Underload sensitivity selection
OFF Position - Normal(default)
See SubDrive/MonoDrive Installation Manual for more information .
#4 Switch
Steady Flow - Control selection
OFF Position - Standard(default)
See SubDrive/MonoDrive Installation Manual for more information .
Configuration Switch SW1
See chart below for appropriate controller
setting. Reference the SubDrive/MonoDrive
Installation Manual or inside of lid for
more information.
Feed the motor leads through
the large enclosure opening and
Output to Motor
securely attach to the terminals
matching the lead colors.
Red Yel Blk
(Output)
Motor Cable
SubDrive100
SubDrive150
1 hp (pump)*
1 .5 hp (pump)*
SubDrive100
SubDrive150
1 .5 hp (pump)
2 hp (pump)
SubDrive100
SubDrive150
2 hp (pump)
3 hp (pump)
ON Position - Low
ON Position - Steady Flow
4
3
2
1
4
3
2
1
4
3
2
1