4.2.3 Exhaust hose clamp (not included)
WARNING!
Do not operate this compressor in an enclosed area. Use this compressor only in well ventilated areas.
The exhaust from the engine contains carbon monoxide, a poisonous, odorless and invisible gas. Breathing
the gas can cause serious injury, illness and possible death. Avoid inhalation of exhaust gas. Never run the en-
gine in a closed garage or confined area.
•
Place the exhaust hose between the outside and the compres-
sor following the shortest path.
•
Connect the hose to the exhaust outlet using the included clamp.
•
Check the tightness of the clamp.
WARNING!
The exhaust hose can 'reach high temperatures during compressors
operation. Provide to wrap the exhaust hose with fireproof material of
adequate insulation. Keep away from compressor moving parts and
flammable parts (example: wooden pallets).
◊ 4.3
Pistons air compressor pump unit
4.3.1 Recommended lubrificants
The compressed air is generated by a lubricated piston two-stage pump unit.
Before the first start fill the supplied oil up to the indicated level.
Always use 51W-40 oil and a pour point of -10 ° C.
The flame point must be greater than +200 ° C. Daily check the oil level and add oil if necessary.
Recommended oil
FIAC High-Performance
Overfilling with oil will cause premature compressor failure.
Do not overfill.
◊ 4.4
Connecting the compressor to the sources of energy and relative inspections
4.4.1 Istruction for grounding
All electrical maintenance must be performed by specialized
technician.
NOTE FOR MOBILE WORKSHOPS USE:
Before connecting the ground, secure the compressor to the
vehicle chassis by appropriate holder.
•
To protect the operator from electric shock this compressor must
be grounded when in use.
•
Do not disassemble the compressor and do not make any other
connections.
•
Any repair must be performed only by authorized service center.
•
REMEMBER: the grounding conductor to the earth is green or
yellow / green.
•
Never connect the grounding conductor to a line termi-
nal.