Pressure Adjustment - Fiac AB598 Normas Generales Para La Instalacion, Uso Y Mantenimiento

Motocompresor y generador
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EN
In order to use the compressor in complete safety read the safety standards before reading this section.
4.5.2 Start
Before start:
- Ensure all guards and panels are securely in place and well fastened.
- Ensure that the exhaust hose is placed in a open area.
- Ensure that the air supply is sufficient.
- Note for mobile workshops: ensure that all tailgates or doors are open.
NOTE: DO NOT START THE COMPRESSOR WITH GUARDS OR PANELS OPEN!
Start and use of compressor is reserved only by specialised personnel.
Manual Start:
Check the accelerator A (located on the left side
of the motor) it must be positioned about halfway.
Then start the engine using the handle B.
Electric start
Start the engine using the key C:
first click: warning lights ON
second click: start engine.
NB refer to the engine manual for the meaning
of the warning lights and for further nformation.
4.5.3 Pressure adjustment
You do not have to use the maximum operating pressure at all times. On the contrary, the pneumatic tool being used
often requires less pressure.
To adjust the working pressure:
Unlock the regulator by pulling it upwards.
Turn to adjust
Push down to lock
1. Tank pressure gauge
2. Pressure regolator
3. Air outlet pressure gauge
4. Quick coupling
Check the manufacturer's maximum pressure rating for tools connected to the compressor and accessories.
Compressor outlet pressure must be regulated so as to never exceed the maximum pressure rating for tools connected
to the compressor.
MSU - P max. 12 bar
A
14
B
1
2
3
C
4

Publicidad