Features And Controls - Briggs & Stratton PGMA G200 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Features and Controls

Read this Operator's Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls
and adjustments. Save this manual for future reference.
A
B
C
D
E
F
G
H
J
K
L
A - Start Switch — Turn key to START ( ) position to
start the engine. Turn key to OFF (0) position to
switch off engine.
B - Hour Meter — Displays and records how many
hours your generator has run (up to 9,999.9).
C - Rocker Switch Circuit Breaker — The
120/240 Volt AC, 30A locking receptacle is
provided with a 2 pole rocker switch circuit breaker
to protect the generator against electrical overload.
D - Choke Control — Used when starting a cold
engine.
E - Battery Float Charger Jack — Use battery float
charger jack to keep the starting battery charged
and ready for use.
F - 120/240 Volt AC, 30 Amp Locking Receptacle
— May be used to supply electrical power for the
operation of 120 and/or 240 Volt AC, 30 Amp,
single phase, 60 Hz electrical, lighting, appliance,
tool and motor loads.
G - 120 Volt AC, 20 Amp, GFCI Duplex Receptacles
— May be used to supply electrical power for the
operation of 120 Volt AC, 20 Amp, single phase,
60 Hz electrical, lighting, appliance, tool and motor
loads.
H - Circuit Breakers (AC) — The 120 Volt AC, 20A
GFCI duplex receptacles are provided with "push
to reset" circuit breakers to protect the generator
against electrical overload.
14
J - Oil Fill Cap/Dipstick — Check and add engine oil
here.
K - Oil Drain Plug — Drain engine oil here.
L - Grounding Fastener — Consult your local agency
having jurisdiction for grounding requirements in
your area.
M - Spark Arrester Muffler — Exhaust muffler lowers
engine noise and is equipped with a spark arrester
screen.
N - Air Cleaner — Protects engine by filtering dust
and debris out of intake air.
P - Recoil Starter — Used to start the engine
manually.
Q - Fuel Valve — Used to turn fuel supply on and off to
engine.
R - Fuel Tank — Capacity of seven (7) U.S. gallons
(26.5 l).
Items Not Shown:
Engine Identification — Provides model, type and
code of engine. Please have these readily available if
calling for assistance.
Identification Label — Provides model and serial
number of generator. Please have these readily
available if calling for assistance.