- Electrical protection of the pendant control :
class 2.
- Fuse protecting the command, in the electrical
box.
- Hooks with safety latch.
The single-phase motor is protected against
excessive warm-ups by a probe inserted into the
coil. This probe prohibits operation by interrupting
the control circuit as long as the temperature of the
coil is not back to an acceptable value. In case of
intensive work or high duty, we suggest to allow a
15 minutes break every 15 minutes of work to avoid
overheating.
2.3
Description of the work or control station
"Up" and "down" hoist movements are controlled
from the pendant control.
Never stand under the load.
In case of a command error, wait for a complete
stop
of
motion
before
command. The control buttons are held type
buttons.
Limit stops are not operating devices but safety
devices. They should therefore not be used
voluntarily but only serve as shutoff devices in case
of involuntary exceedance of the expected travel.
Never stay or work under load. If necessary, have a
barrier of security on the floor around the area at the
vertical of the load.
Avoid heavy slipping: Wait for a complete
stop
of
your
installation
movement.
Check regularly that no obstacle is located along the
path of movement (above and below the load).
2.4
Normal use
This hoist is designed for lifting loads.
It is designed for professionals involved, for
example, in work in elevator shafts or on
façades.
Press on «» to lift and on «» to lower.
Release the buttons to stop the movement.
If it is not stopped, press the Emergency
Stop. If it is not working, remove the main
plug and have your hoist maintained.
INSTRUCTION MANUAL
Electrical winches LM+
performing
another
before
resuming
2.5
Decommissioning
After work, or during an prolonged shutdown, or if
preventive maintenance tests (see §3) are not
satisfactory, put your load on the floor or a secure
access level. Disconnect the hook from the load
when it is resting stable on a fixed and solid
support.
The device can remain attached provided that it is
protected from the weather and in a dry place.
Snap your emergency stop.
Unplug and store your pendant control box.
Store your power supply cable.
2.6
Warnings about contraindications
It is forbidden to use this product:
- if you are not a trained professional
- to exert a force or lift a load greater than the
WLL (450kg) if it is not described in this
manual,
- to lift people,
- in harsh conditions (extreme or corrosive
environment, high magnetic fields, etc.)
- in potentially explosive atmospheres
- to perform work on energized power lines,
- to carry loads themselves dangerous (molten
metals, acids, bases, radioactive material,
fragile loads etc)
- in combination with other lifting equipment if
it is not listed in this instruction manual,
- with loads with a wind surface area >2 m² if it
is not listed in this manual,
- with a wireless remote control system not
mentioned in this manual
- in the event of specific risks (wind> 14 m / s,
T ° <-10 ° C or> 55 ° C, storms etc)
- with worn or deformed cables
- with
lubricated
containing bisulphite or MoS2 (Molykote ®,
etc)
- To apply a load on the loose strand of the
hoist.
- To use the wire rope as a means to sling the
load
2.7
Residual risks
The use of cable damaged or not suited to the
device is the major risk of accident and failure.
Check that your equipment has not been
subject to vandalism, theft, or damage.
Réf : 1813000204
Page : 11/20
Version : 46/18
cables
with
products