2. SPECIFICATIONS

2.1 Technical data for the swimming pool heat pump unit

Models
Heating capacity*
Absorbed electrical power *
Running current*
Power supply
aM type fuse calibre
Curve D circuit breaker
Compressor quantity
Type of compressor
Refrigerant
GWP
Charge R410A
Teq CO2
Fan quantity
Fan power
Fan rotation speed
Ventilation
Sound pressure level
(at 10 metre)
Hydraulic connection
Nominal water flow*
Water pressure drop (max)
Unit net dimensions (L/l/h)
Net weight per unit
* Value at +/- 5% under the following conditions: Exterior temperature = 15°C (59°F) / HR = 71% /
Water inflow temperature = 26°C (78.8°F).
In accordance with the NF -414 standard (annual use)
2
ENERGYLINE PRO
ENP6MASCA
kW
17,8
kW
3,69
A
16,2
V
230V
50Hz
Ph/Hz
A
20
A
20
1
Scroll
R410A
2088
kg
2,3
4,80
2
W
50 — 225
RPM
600 — 950
Horizontal
dB(A)
45
mm
50
m
/h
6,6
3
kPa
7
mm
1138 / 470 / 1264 1138 / 470 / 1264
kg
127
ENP6TASCA
ENP7TASCA
18,2
3,7
7,69 / 6,89 / 6,33
9,71 / 8,01 / 7,70
400V 3N
50Hz
400V 3N
12
12
1
Scroll
R410A
R410A
2088
2,3
4,80
2
50 — 225
50 — 225
830 — 960
800 — 1050
Horizontal
Horizontal
45
50
6,6
7
1138 /470 / 1264
123
23,4
5,15
50Hz
16
16
1
Scroll
2088
2,8
5,85
2
47
50
8
18
140

Publicidad