PARAMETER
VALUE
riLA
0
1 - 10
i.Adi
no
Si
FinE
no
Si
DESCRIPTION
Motor release on closing limit switch
When the door halts against the closing limit switch, the motor is
controlled for a fraction of a second in the opposite direction, decreasing
the motor gear tension
Function disabled
Time motor release (max. 1 second)
Enabling the ADI device
This menu makes it possible to enable operation of the device connected
to the ADI connector.
Si
PLEASE NOTE: selecting
and pressing MENU accesses the
configuration menu for the device connected to the ADI connector.
This menu is managed by the device itself and is different for each device.
Refer to the manual of the device for programming.
Si
If the
option is selected, but no device is connected, the display will
show a series of dotted lines. Exiting the ADI device configuration menu
i.Adi
returns to the
option
Interface disabled, any signals will be ignored
Interface enabled
End of programming
From this menu you can save any modified parameters and finish the
programming phase
Do not exit the programming menu
Stores the settings and exits the programming menu
- 42 -
DEFAULT
MEMO
0
no
no