8 Quick Installation Guide – EuroFlex
24 VDC control supply and filter
EuroFlex requires a 20-30 VDC, 1 A supply to power the control
electronics.
Connect the control supply at connector X9, observing the correct
polarity. A fused DC supply should be provided for the EuroFlex.
If other devices are to be powered from the same 24 V supply, a
filter (part FI0014A00) should be installed to isolate the EuroFlex
from the rest of the system.
Motor U V W outputs
Connect the motor to the U, V and W outputs at connector X2.
The U, V and W outputs must be connected to their corresponding
U, V or W terminal on the motor. Mis-connection may result in
uncontrolled motor movement.
Motor feedback input
Connect the motor feedback signal to connector X8.
The EuroFlex operates with incremental encoder
feedback devices. The device type is configured using
the supplied software, Mint WorkBench. Suitable
cables are available.
Encoder output
The encoder output at connector X7 can be used to
transmit axis position to another controller or host
positioner.
Serial communication
The EuroFlex communicates with the host PC using
RS485 communication.
Connect a suitable cable between connector X6 and
the host PC's RS485 port.
24V IN X9
POWER OUT X2
1 CHA+
2 CHB+
1
9
3 CHZ+
4 Sense
5 Hall U-
6 Hall U+
15
8
7 Hall V-
8 Hall V+
FEEDBACK IN X8
1 CHA+
1
6
2 CHB+
3 CHZ+
4 (NC)
9
5
5 DGND
ENCODER OUT X7
1 (NC)
1
6
2 RX-
3 TX-
4 (NC)
9
5
5 DGND
COMMS X6
0V
+24V
EARTH
EARTH
W
V
U
9 CHA-
10 CHB-
11 CHZ-
12 +5 V out
13 DGND
14 Hall W-
15 Hall W+
6 CHA-
7 CHB-
8 CHZ-
9 (NC)
6 (NC)
7 TX+
8 RX+
9 Shield