FIRE DAMPERS
The fire damper should be easily handled and its position must be distinguished from the outside through the adjustment knob.
The fire damper must remain fixed in its position and must not be able to close automatically.
The fire dumper must NOT close the flue section completely, but it must guarantee a permanent minimum opening which should
be equal to 3 % of the section itself and in any case equal to at least 20 cm2.
CHIMNEY POT
The chimney pot must have a wind guard (for any clarification, please refer to your retailer), an internal section equivalent to that
of the flue, and smoke outlet cross-section at least twice that of the internal flue cross-section.
For correct operation, please refer toUNI 10683/2005.
AIR INTAKE
The room of installation must have a suitable outside air intake with a through surface area of at least 200 cm2 (Ø 16), in order to
replenish the burnt oxygen and ensure an adequate combustion air flow.
SAFETY DISTANCES
- Place the stove away from flammable materials and objects; leave a distance of 80 cm from furniture and at least 10 cm from the
wall. These distances are for furniture or walls which are either fireproof or able to withstand being raised to an environmental
temperature of 80°C without overheating to the point of catching fire. The air circulation which is created around the stove thanks
to these distances ensures efficient ventilation and improves thermal efficiency.
- In the event the stove is to be installed on a floor made with a flammable material, we recommend placing it on a steel plate
available as an optional.
EDILKAMIN declines any responsibility for installations not complying with the laws in force and for misuse of the stove.
- 18
-