Valve terminal type CPV...−GE−ASI−4E4A−...−CE has been
designed exclusively for controlling pneumatic actuators
and for use in bus systems in accordance with AS−Interface
specification 3.0. If used together with additional commer
cially available components, such as sensors and actuators,
the specified limits for pressures, temperatures, electrical
data, torques etc. must be observed.
AS−Interface bus systems and valve terminals may only be
installed by personnel especially trained for this purpose.
Specifications on the design and addressing of your bus sys
tem can be found in the manual for the AS−Interface master.
Detailed information on the pneumatic components of the
valve terminal can be found in the Pneumatics manual
P.BE−CPV−...
Warning
S Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S Connect one of the earth cables on the end plates
with low impedance (short cable with large
cross−sectional area) to the earth potential.
S Commission only a valve terminal which has been
fitted and wired completely.
Festo CPV...−GE−ASI−4E4A−...−CE
instructionsEnglish
0703NH
English
15