Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS
Systems. Failure to heed these warnings will void your warranty.
UPS Location Warnings
• The UPS is designed for indoor use only in a controlled
environment, away from excess moisture, heat/cold, conductive
contaminants, dust or direct sunlight.
• Leave adequate space around all sides of the UPS for proper
ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power
outlet. Do not plug the UPS into itself; this will damage the UPS.
• Do not modify the UPS's plug, and do not use an adapter that
would eliminate the UPS's ground connection.
• Do not use extension cords to connect the UPS to an AC outlet.
Your warranty will be voided if anything other than Tripp Lite
surge suppressors are used to connect your UPS to an outlet.
• If the UPS receives power from a motor-powered AC generator,
the generator must provide clean, filtered, computer-grade output.
Equipment Connection Warnings
• Do not use Tripp Lite UPS Systems for life support applications in
which a malfunction or failure of a Tripp Lite UPS System could
cause failure or significantly alter the performance of a life support
device.
Quick Installation
STEP 1: Place the UPS in either a horizontal or vertical ("tower")
position. The UPS's housing is designed with sides that slope
slightly in order to tilt the LCD Display up for easy viewing in
either position—horizontal or vertical. As another aid to easy
viewing, the LCD Display can be rotated. To rotate the display:
carefully insert a small tool in the slots on the sides of the display
to pop it out of the UPS housing; rotate the display, and snap it back
into the UPS housing.
CAUTION: To safely balance the UPS when it is placed in a
vertical ("tower") position, make sure the LCD Display is
located at the top of the front panel.
STEP 2: Using your computer's detachable power cord, plug the
UPS into a wall outlet. Remove your computer's detachable
power cord. Insert the female plug of the computer's cord
your UPS's AC input. Insert the male plug of your computer's
cord into an AC wall outlet that does not share a circuit with a
heavy electrical load (such as an air conditioner or refrigerator).
After plugging the UPS into a wall outlet, push the ON/OFF button
for one second to turn the UPS on (see Basic Operation section).
Please Note! The UPS will not turn on automatically in the
presence of live utility power.
• Do not connect surge suppressors or extension cords to the output
of your UPS. This might damage the UPS and will void the surge
suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your
UPS for any reason. There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high
short-circuit current. Observe proper precautions. Do not dispose
of the batteries in a fire. Do not open the UPS or batteries. Do not
short or bridge the battery terminals with any object. Unplug and
turn off the UPS before performing battery replacement. Use tools
with insulated handles. There are no user-serviceable parts inside
the UPS. Battery replacement should be performed only by
authorized service personnel using the same number and type of
batteries (sealed Lead-Acid). The batteries are recyclable. Refer to
your local codes for disposal requirements or in the USA only call
1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-822-8837) or
visit www.rbrc.com for recycling information. Tripp Lite offers a
complete line of replacement batteries at www.tripplite.com.
• Do not attempt to add external batteries to the UPS.
STEP 3: Plug your equipment into the UPS.* Insert the female plug
of the detachable power cord that came with your UPS
computer's AC input. Insert the UPS cord's male plug into any of
your UPS's female output receptacles. Select outlets (see diagram)
will provide battery backup and surge protection; plug your
computer, monitor and other critical devices here. Select outlets
(see diagram) will provide surge protection only; plug your printer
and other non-essential devices here.
* Your UPS is designed to support electronic equipment only. You will overload the
UPS if the total VA ratings for all the equipment you connect to the Battery Backup
Protected/Surge Protected outlets exceeds the UPS's Output Capacity. To find your
equipment's VA ratings, look on their nameplates. If the equipment is listed in amps,
multiply the number of amps by 230 to determine VA. (Example: 1 amp × 230 = 230
VA). If you are unsure if you have overloaded the Battery Backup Protected/Surge
into
B
Protected outlets, run a self-test (see "MUTE/TEST" Button description).
CAUTION: The UPS must be plugged into a live AC outlet and
turned on for 24 hours after initial installation to fully charge the
UPS's internal battery. Your connected equipment will receive
utility-supplied AC power (if present) immediately after the UPS
is plugged in and turned on; however, your connected equipment
may not receive full battery backup in the event of a blackout or
severe brownout unless the UPS's internal battery is fully charged.
2
into the
A