The regulator will display the relative humidity of the atmosphere by defect. By pressing
the UP button, you can also visualise ambient air temperature, the condition of the unit (ON/OFF),
and the resistor temperatures.
◙ USER MENU
By pressing the (ENTER) button for 5 seconds, you can access the USER menu. This menu
displays the following parameters:
SET: Allows for the setting of a specific temperature (SET-POINT Temperature). Once the
specific temperature is reached in the area, the Heating function of the Dehumidifier will turn off.
SEH: Allows for the setting of a specific relative humidity (SET-POINT Humidity). Once
the specific humidity is reached in the area, the Dehumidifying function will turn off.
OPCIONAL: Only for units with time card.
hh: Adjusts the hour (from 0 to 23)
nn: Adjusts the minutes (from 0 to 59)
dAY: Adjusts the day of the week (from 0 to 6) (0 = Monday / 6 = Sunday)
Pr1: Unit programming (0 = Programmed / 1 = Manual)
If Manual operation is chosen, the machine will operate continuously, following the
specified parameters regulated by SET and SEH. Factory setting will be ignored.
If Programmed operation is chosen, the machine will operate following factory settings of
SET and SEH, within the specified times. Outside of these times, the machine will not operate.
If PR = 1 is chosen, it is not necessary to establish any parameters. The machine is already
adjusted.
If PR = 0 is chosen, the following parameters must be programmed depending on your
needs.
Ud: Days the unit should operate (1 = Every day. 2 = From Monday to Friday. 3 = From
Monday to Saturday).
Us: Selection of one or two Programme Cycles (1 = One Programme Cycle. 2 = Two
Programme Cycles).
If Us = 1 is chosen, only the DH1, Dn1, DH2 and Dn2 parameters need be programmed.
If Us = 2 is chosen, the following parameters will need to be programmed:
DH1: Hour of unit start-up (1st cycle)
Dn1: Minute of unit start-up (1st cycle)
DH2: Hour of unit shutdown (1st cycle)
Dn2: Minute of unit shutdown (1st cycle)
DH3: Hour of unit start-up (2nd cycle)
Dn3: Minute of unit start-up (2nd cycle)
DH4: Hour of unit shutdown (2nd cycle)
Dn4: Minute of unit shutdown (2nd cycle)