Before installing the connections, be sure to
disconnect the electricity so that the power
supply is turned off.
Connect the power supply wires to the
machine's input terminal.
Connect the grounding wire to its
corresponding terminal.
All local and national electricity codes
concerning the protection of defects in electric
power lines should be respected at all times
during the electrical installation.
Verify the torque of all electrical
connections.
The electrical resistance between the
ground and any electric terminal will be verified
to be over 1 megaohm.
In the case of fluctuations in the power
supply, a power supply stabilising system is
recommended in order to protect the equipment.
Always check that the supply voltage corresponds with the voltage which appears on the technical
characteristics nameplate of the equipment.
All wiring should comply with local and national electric codes and should not be prone to
overheating and subsequent voltage failures. As a guide, you can use the table shown below for
lengths of less than 5 meters. All local and national codes should be respected at all times.
General Power Supply
Voltage. (V)
Section (mm2)
No. of wires
General Power Supply
Voltage. (V)
Section (mm2)
No. of wires
13. HYDRAULIC CONNECTIONS.
Always respect the hydraulic connection diameters specified for each machine.
A full-flow shut-off valve should be installed on each of the hydraulic elements in the
equipment, so that each of these may be isolated if needed (for repairs, substitutions, etc.) without
the need to drain the circuit.
Anti-vibration dampers should be installed in the inlet and outlet of the machine, in order to
avoid vibrations which may cause cracks or breakage in the hydraulic connections.
In order to avoid possible breakage, do not force the copper tubes connected to the water
supply.
CDP-2+E
220 II
380 III
4
2P+
4P+
Ground
Ground
Ground
CDP-2 (+A)
220 II
380 III
2.5
2P+
4P+
Ground
Ground
Ground
MODEL
CDP-3+E
220 II
380 III
220 II
4
2P+
4P+
Ground
Ground
CDP-3(+A)
220 II
380 III
220 II
2.5
2P+
4P+
Ground
Ground
ENGLISH
CDP-4+E
380 III
220 II
6
2P+
4P+
2P+
Ground
Ground
CDP-4(+A)
380 III
220 II
2.5
2P+
4P+
2P+
Ground
Ground
CDP-5+E
380 III
6
4P+
Ground
CDP-5(+A)
380 III
2.5
4P+
Ground
36