3. Self learning of the forces
-
Press the
key,
3
the display shows
m
PLEASE NOTE: On completion of the procedure, it is possible to exit the programming procedure, storing the parameters
set: press and hold the
key for 5 seconds until the segments of the display illuminate one at a time until showing
4. Adjusting the sensitivity (default: 4)
This menu allows the sensitivity of the device, when the door encounters an obstacle, to be increased or decreased.
This parameter is already set to a mid value (4) that should be ideal for the majority of installations.
-
Press the
key,
4
the display shows
Press the
key to save
the settings: the display
4
shows
6. Open alarm (default: 0 – function deactivated)
If this function is activated, the device emits BEEPs for 30 seconds when the door remains open for longer than 10 minutes. The alarm is
repeated every 10 minutes. Close to door to interrupt the alarm.
-
Press the
key,
6
the display shows
Press the
key:
3
flashes - the door opens
Press the key
:
0
flashes
m
PLEASE NOTE: if this parameter is modified, then on completion of programming, it is
necessary to conduct a complete open/close cycle, during which the control unit automatically
conducts a fresh force training operation (during this cycle, the motor works at maximum force,
so particular attention must be paid).
0
Press the
key:
flashes
to indicate that the function
is deactivated
When the door stops, press
the
key to confirm.
Press the
key once more
to continue - the door closes
Select the desired level using the + and – keys
Press the + key to activate
the function: the display
I
shows
21
When the door stops, press the
key to save the settings.
3
The display shows
0
Press the
key to save
the settings: the display
6
shows