AUT-WIG
2.6 Emergency information
In case of emergency, immediately interrupt the following supplies:
• Electrical power supply
• Coolant supply
• Compressed air supply
• Gas supply
Further measures can be found in the "Power source" operating instructions or in the
documentation of further peripheral devices.
3 Product Description
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert and modify the device to enhance its performance without authorization.
• Only qualified personnel are permitted to perform work on the device or system.
3.1 Technical Data
Ambient temperature Welding
Transport and storage
Relative humidity
Tab. 1
Physical conditions
Type of voltage
DC polarity of the electrodes
Type of use
Voltage rating
Max. arc ignition and stabilization voltage
Protection type of the machine-side
connections (EN 60 529)
Shielding gas (DIN EN ISO 14175)
Electrode
Tab. 2
General torch data (EN 60 974-7)
BAL.0166 • 2019-01-03
- 10 °C to + 40 °C
- 25 °C to + 55°C
up to 90 % at 20 °C
DC or AC
Usually negative
automatic
141 V peak value
6 kV
IP2X
Argon
industry standard tungsten electrodes suitable for
TIG use, preferably low radiation
3 Product Description
EN - 5