Type
Pin 1
Operating voltage connection for
electronics
Rated value
Tolerance
Current consumption
Pin 2
Load voltage connection
Rated value
Tolerance
Current consumption
Residual ripple
Electrical isolation
Valves
Detailed information on the CPV Direct DN2 can be found
in the manual P.BE−CP−DN2−.. .
22
CPV..−GE−DN2−8
24 V DC (protection against
incorrect polarity, fused in
ternally, switches on again
automatically)
20.4...26.4 V
Max. 200 mA
24 V DC (protection against
incorrect polarity, fused in
ternally, switches on again
automatically)
20.4...26.4 V
Sum of all switched−on CP
solenoid valves; see manual
CP pneumatics"
4 Vpp (within tolerance)
Bus interface opto−
decoupled
See Pneumatics manual
P.BE−CPV−..