Safety Stop Function
15 14 13
12
11
1 1 0 0 = with
0 0 = control circuit
braking
is supplied from an
IGBT
external +24 Vdc
1 =
power supply
without
1 = control circuit
braking
is fed by the
IGBT.
inverter SMPS.
Hexadecimal
digit #4
2 INSTALLATION
XC25 Terminals
1
STO1
2
GND1
3
STO2
4
GND2
NOTE!
XC25:2 and XC25:4 terminals are not connected internally to inverter +24 V power
supply reference. In most of cases, those terminals are connected to XC1:11 control
terminal in CFW-11 and CFW-11M inverters and to XC1:36 in CFW70X inverters.
NOTE!
Follow the instructions provided on item 3.2.5 (CFW-11 and CFW70x) or 3.4.8
(CFW-11M) of User's Manual.
For XC25 control cabling consider the following:
Use wire gauge from 0.5 mm
torque of maximum 0.50 N.m (4.50 lbf.in).
Use shielded cables connected to ground only on inverter side (use the provided metallic
pieces as shown on figure 3).
Run the cables separated from the remaining circuits (power, 110 V/220 Vac control, etc.).
8 | CFW-11, CFW-11M, CFW70X
Table 1: Content of P0029 parameter
10
9
0 = inverter
without
safety stop
option
1 = inverter
with safety
stop option.
Hexadecimal
digit #3
Table 2: XC25 terminals (safety stop terminals) signals
Function
Terminal 1 of
safety relay K1 coil.
Terminal 2 of
safety relay K1 coil.
Terminal 1 of
safety relay K2 coil.
Terminal 2 of
safety relay K2 coil.
(20 AWG) to 1.5 mm
2
Bits
8
7
0 =
Voltage rating of
Inverter
the inverter:
without
00 = 200...240 V
RFI filter
/ or 220/230 V
1=
01 = 380...480 V
inverter
10 = 500...600 V
with RFI
11 = 500...690 V
filter.
or 660/690 V
Hexadecimal
Specifications
Coil rated voltage: 24 V, range: 20...30 Vdc
Coil resistance: 960 Ω ± 10 % @ 20 °C (68 °F).
Coil rated voltage: 24 V, range: 20...30 Vdc
Coil resistance: 960 Ω ± 10 % @ 20 °C (68 °F).
(14 AWG) and maximum tightening
2
6
5 4 3 2 1 0
Inverter output
rated current.
Hexadecimal
digit #2
digit #1